Configuration of Logic of Standard Switch Option Selections
Option
SW1
SW2
SW3
L1
Normally Open,
PNP
Not Supplied
Not Supplied
L2
Normally Closed,
PNP
Normally Closed,
PNP
Not Supplied
L3
Normally Open,
PNP
Normally Closed,
PNP
Normally Closed,
PNP
L4
Normally Open,
NPN
Not Supplied
Not Supplied
L5
Normally Closed,
NPN
Normally Closed,
NPN
Not Supplied
L6
Normally Open,
NPN
Normally Closed,
NPN
Normally Closed,
NPN
Switch Type
Exlar Part
Number
Supplier Part Number
Normally Closed
Switch, PNP
43404
Turck P/N: BIM-UNT-RP6X
Normally Open
Switch, PNP
43403
Turck P/N: BIM-UNT-AP6X
Normally Closed
Switch, NPN
67635
Turck P/N: BIM-UNT-RN6X
Normally Open
Switch, NPN
67634
Turck P/N: BIM-UNT-AN6X
See switch manufacturer’s documentation for additional limit switch
information.