![EXFO Power Blazer 88200NGE User Manual Download Page 518](http://html1.mh-extra.com/html/exfo/power-blazer-88200nge/power-blazer-88200nge_user-manual_2449938518.webp)
Test Results
508
88000 Series
PTP Stats
PTP Stats
From the
Test
menu, tap
Results
, and the
PTP Stats
tab.
TX/RX PTP Message Count/Rate
Gives the transmitted/received count and average rate for each PTP
message, and the total count for all messages.
Note:
In the case where messages are lost while the Receipt Timeout is set to a
large value (slow communication), the last valid recorded rate value will
be preceded with
<
to indicate that the reception rate is not stable. This
applies to
Delay Resp
,
Announce
,
Sync
, and
Follow UP
.
Note:
When the rate is above 150 messages/s,
> 150
is displayed.
TX
RX
Signaling Announce Req
a
Signaling Sync Req
Signaling Delay Resp Req
Delay Req
a.
The rate value corresponds to an average rate because these messages are only
transmitted/received when negotiating or renewing the lease with the Grand Master
clock. If the connection with the Grand Master Clock was already established when the
test is started, the
0
value is displayed. However, the value becomes available with the
next lease renewal which happens every 150 seconds. Only available with G.8265.1
profile.
Signaling Announce Grant
Signaling Sync Grant
Signaling Delay Resp Grant
Delay Resp
Sync
Follow Up
Announce
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...