background image

Setting Up Tests

Viewing Test Results

Once a test has run, the results obtained are displayed on the screen. 

Saving Test Results

To set parameter values and save or export results:

Press the up/down arrows to select the desired parameter.

Press the left/right arrow keys to view and select the options,
OR
Press 

 to open the on-screen keyboard to enter or edit a value.

Press the up/down left/right arrows to navigate the on-screen keyboard.

To read/upload/export/delete saved results:

Reading Saved Test Results

To setup the Dialer function:

From the 

Copper Main 

or 

Multimeter

 (if FED option enabled) menu, select 

Dialer 

and press

.

Set up the following parameters as needed.

Running Tests

To run a test:

From the 

Copper Main 

pane, select the desired test icon and sub-menu icon in the case of 

Multimeter

Noise 

and 

Frequency Tests

TDR

, and 

Auto Test

, and press 

. The test automatically runs if the 

Setup

/

Application Settings

 - 

Test Startup Mode

 is set to 

Auto

. If not, press Start/Stop key to run the test.

You can save test results to an internal memory file or export results to an HTML, MHTML, or XML report using 
a USB key, during or after a test. Each copper test includes a 

Save Result

 tab opening a new screen to do so.

Note: User Auto Test

 includes an 

Upload/Save Result

 tab which 

adds an 

Upload & Save

 button, and allows you to upload saved 

Auto Test

 results to an FTP site or USB.

Select the desired function key to complete your selection.

From the 

Enter Number

 entry, press 

 to open the on-screen 

keypad. 

Enter phone numbers using the key pad and add them to the Phone 
Book by pressing the 

Add to PhoneBook

 function key.

Enter an 

Entry Name

 for the 

Phone Number

, select the 

Type

, and 

Add

 it. The Phone Book can include a maximum of 50 groups.

You can also setup the 

Phone Book

 from the 

Setup

 icon, described 

below.

POTS dialing is also integrated into individual test screens to give you 
quick access to the manual dialer function, speed dial and last dialed 
lists, without exiting the current test application.

To select a test profile:

To Setup parameters common to all tests:

From the 

Copper Main 

menu, select 

Test Configuration 

and press

.

From the 

Copper Main 

menu, select 

Setup 

and press

.

Select Profile

 to list and choose a profile already saved in the internal 

memory.

Select 

Profile Details

 to view any of the saved test threshold values and 

cable parameters.

From this function, you can also perform the following:

Copy a test profile to a USB from the unit’s internal memory and vice 
versa.

Delete a profile from the unit (except the default profile).

Reset the current test setup to the factory default profile by selecting 

Profile Default

.

Save changes made to selected profile.

Select from the following menu items to setup copper tests:

Phone Book

 to setup and save groups of phone numbers.

Cable Book

 to select, add, clone, and delete a cable, as well as modify 

its details; and load and save a Cable Book.

Application Settings

 to set up and save software settings and values 

for the cables, using the following pages: 

General

Standard

Identification

File Name

, and 

Buzzer

The 

General

 tab also allows you to configure graph-viewing modes. 

And 

Capacitance Measurement

 allows for 2- or 3-terminal testing.

Factory Default

 to revert the 

Phone Book

 and/or 

Application 

Settings

 to the factory default values.

Test Lead Compensation

 to overwrite the current test lead 

characteristics and start resistance and capacitance compensation 
based on the cable temperature of the test lead.

Select Result File

 to save your results to an existing 

File Name 

or 

Upload 

& Save

 your 

User AutoTest

 results to an FTP site or USB. 

OR
Select 

Save

 or 

Export

 buttons and press 

 to confirm your selection.

The file format for exporting results is 

HTML

MHTML

, or 

XML

.

Multimeter

Tests included are: 

Voltage

Current

Resistance

/

Shorts

Resistive 

Balance

Isolation

Capacitance

/

Opens

Station Ground

, and 

Stressed 

Balance

 (if option enabled). Select an icon to run a test, which will then 

display pass/fail status and detailed test results.

The 

Dialer

 can be accessed from the 

Copper Main

 or 

Multimeter

 (if FED 

option enabled) menu, and is integrated into all tests to give you quick access 
to the manual dialer function, speed dial and last dialed lists, without exiting 
the current test application.

Threshold Settings

 can be set within each test.

Pair Detective

Summary

 displays the pass/fail status, the detected device, 

DC-Voltage/Current and Isolation for each selected inactive wire pair, as well 
as other detailed results.

Isolation

 results display a five-level indicator of the measured isolation.

Isolation Soak Time

Cable Setup

, and 

Threshold Settings

 can be set up 

from the 

Summary

 page.

Multimeter

 tab displays 

DC Voltage

/

Current

 and 

Capacitance

 results, and 

Isolation

 which displays 

Resistance

 and a 

Soak Counter

 for each wire Pair.

TDR

 tab integrates a live TDR test and displays the distance to the most 

significant reflection, in text and graphical measurements.

Noise Tests

Tests included are: 

VF Noise

Power Influence

VF Impulse Noise

WB PSD 

Noise

WB Impulse Noise

, and 

NEXT

. Select an icon to run a test, which will 

then display pass/fail status and detailed test results.

Power Influence

WB PSD Noise

WB Impulse Noise Histogram

, and 

NEXT Spectrum

 display results in graphical format. For 

WB PSD Noise

, you 

can view the graph in either portrait/landscape mode. 
The 

Select Graph

 button opens a new selection of function keys which allow 

you to maneuver the graph.

The 

Dialer

 tab is integrated into all tests to give you quick access to the 

manual dialer function, speed dial and last dialed lists, without exiting the 
current test application.

Threshold Settings

 can be set within each test.

FaultMapper

The 

FaultMapper

 test (a SmartR™ feature) locates bridged taps, shorts, grounds, 

and opens, and displays the cable faults in text and graphical format. 
The 

TDR

 tab provides a shortcut to the TDR test.

Results Summary

 tab allows you to select a 

File Name

 and view the results 

from a list of files previously saved in the 

MT internal memory

 or a 

USB

.

From the selected results sub-menu, you can view the following:

Summary

 for test status, general and identification information.

Result Details

 for measured results for each lead combination and cable 

parameters of the test.

Profile Details

 to view thresholds and setup parameters of the test.

Phone Book

 for the phone entry dialed during the test. If the dialer was not 

used during the test, the Phone Book icon will not appear.

FED Details

 displays the 

FED

 (far end device) 

State

 value for the test.

Upload

 tab initializes a Wi-Fi or Ethernet connection and allows you to 

upload previously saved User Auto Test files to an 

FTP

 site or 

USB

. The 

Delete

 button is for deleting selected XML files in internal memory.

Export

 tab allows you to select a 

File Name

 or 

All

 files previously saved and 

export the results in the following 

Report Format

HTML

MHTML

, or 

XML

.

Delete

 tab allows you to delete a selected 

File Name

 or 

All

 files saved in the 

MT internal memory

 only.

From the 

Copper Main 

pane, select 

Result Manager. 

The 

Pair Detective

 test (a SmartR™ feature) consists of a series of ten 

consecutive individual tests and applies a high voltage to the line during isolation 
testing.

Note:

Before proceeding with this test, ensure the line is inactive.

1
2

1

2

3

4

1

2

1
2

3

4

5

6

Reviews: