CM-ECCS-U441TB
Page 5 of 7
[email protected] www.excelwavetechnologies.com 1-888-329-2878(Tel) 1-888-318-5528(Fax) Rev.2
©All rights reserved, 2018
Connection Check List
Measurement
VNA Connection and Configuration
Port1
Port2
Load Measure
Output Power
Gain
ANT
RX1
TX
S21
-20dBm
VSWR(Rx1)
ANT
RX1
TX
S22
-20dBm
Out of Band Rejection (TX-RX)
ANT
RX1
TX
S21
-20dBm
Isolation (RX1-RX2)
RX2
RX1
ANT
S12
-20dBm
Insertion Loss (ANT-TX1)
ANT
TX1
RX
S12
VSWR (ANT)
ANT
TX1
RX
S11
VSWR (TX1)
ANT
TX1
RX
S22
Isolation (ANT-TX1)
ANT
TX1
RX
S21
Out of Band Rejection (RX-TX)
ANT
TX1
RX
S12
Tuning Procedure
1.
Flip over the unit, put it on a flat rubberized surface.
2.
Remove the 4 screws for the cover on the bottom of the unit as show in Fig.6
Fig.6 Remove the cover
3.
Slightly loosen the nuts for tuning rods with the supplied socket wrench.