Output Mating Connectors

J3: Locking Molex 51110-0860; Non Locking Molex 51110-

0850; Crimp Terminal: Molex p/n 50394. 

J4: M4 Screw

9

www.excelsys.com

J3

J4

Voltage 
Adjust

M4 Screws

2    1 

2

1

J3

J4

V1 Adjust

2     1 

V2 Adjust

Type A: 

powerMods

Type B: 

powerMod

XgA to XgE

XgF

XgG to XgL

Output Signals and Power Connector Pinout

Pin   

J3

J3 

J3 

J3              J4  

J4  

Module    (XgA to  XgD)    (XgG to XgL)       (XgE)

(XgF)        (Type A)    (Type B)

1               not used           +Sense

not used          - pg (V2)         -Vout          -V2  

2               Common           -Sense   

not used           +pg (V2)       +Vout          +V2

3               not used              Vtrim

not used          Inhibit V2)                        -V1 

4               not used              Itrim

Common       Common (V2)

+V1

5                +Inhibit         +Inhibit/Enable      -pg

-pg (V1)

6                -Inhibit          -Inhibit/Enable

+pg

+pg (V1)

7               not used

+pg

Inhibit            Inhibit (V1)  

8               not used

-pg

Common       Common (V1)

Output Signals and Power Connector Pinout

Section 4.8

powerMod

Operation and Signals

powerMod

Enable/Inhibit

Each 

powerMod

may  be  enabled/inhibited  by  means  of  an

appropriate signal applied to an opto-isolated input on pins J3

pin 5 (positive) and J3 pin 6 (negative), on 

powerMods

XgG to

XgL.  Inhibit  is  available  by  means  of  an  appropriate  signal

applied to an opto-isolated input on J3 pin7 on XgE, on J3 pin

3 and pin 7 on XgF 

(

the output voltage of the 

powerMod

will be

fully  inhibited  to  0V)  and  pin  J3  pin5(positive)  and  J3  pin  6

(negative) on 

powerMods 

XgA to XgD

Turn-on delay from AC

in and Global Enable is typically 2ms but is load dependant.   

XgA to XgL XgE, XgF

Maximum signal input voltage

12V

0.8V

Minimum signal input voltage

3V

0V

Minimum current required is  

1.7mA

Remote Inhibit/Enable of Output

Output powerMods Power Good Signal

powerMod

Start-Up and Shutdown

powerMods

are  designed  such  that  when  input  power  is

applied, all outputs rise to their set point voltage simultaneously.

Likewise, when input power is removed all outputs commence

to drop simultaneosly and reach Zero potential simultaneously.

Outputs can be sequenced using the enable function in order to

allow controlled start up if required.

See plots for start-up and shutdown characteristics.

Output powerMod Start-Up

Output powerMod Shutdown

UltiMod Designer Manual

Summary of Contents for ultimod

Page 1: ...Designer Manual...

Page 2: ...um positioning of powerMods Do not unplug powerMods while input power is applied to the powerPac The UltiMod is not designed for hot plug applications Do not restrict airflow to the unit The cooling f...

Page 3: ...ts Conversion in the output assemblies is achieved by the most advanced high efficiency converters resulting in reduced UltiMod Designer Manual Designer Manual www excelsys com 3 size for magnetics an...

Page 4: ...meeting the unique requirements of individual users The inherent flexibility resulting from modularity concepts is further enhanced by this flexibility Although the products are very versatile care sh...

Page 5: ...n both Straight line and Foldback modes Straight line Current Limit can be programmed using an external voltage source or resistor potentiometer Connection between the Itrim pin J3 pin4 and the Vout t...

Page 6: ...alues of R1 to R2 required F 0 0468 for XgH CF 1 042 for XgH Imax 36A for XgH Ilim 20 55 5 less than 85 Imax 36 Example To set the current limit of XgH to 20A determine the external voltage to be appl...

Page 7: ...ject to not exceeding the maximum module voltage at the output terminals Observe the following precautions when remote sensing 1 Use separate twisted pairs for power and sense wiring 2 Route the sensi...

Page 8: ...US1 SVT 3100 183 J2 Locking Molex 51110 0850 Non Locking 51110 0860 Crimp Terminal Molex p n 50394 Input Cable Option D The UltiMod Series is also available with an input cable connection option allo...

Page 9: ...3 pin 5 positive and J3 pin 6 negative on powerMods XgG to XgL Inhibit is available by means of an appropriate signal applied to an opto isolated input on J3 pin7 on XgE on J3 pin 3 and pin 7 on XgF t...

Page 10: ...t is 2mA Maximum Collector voltage is 30V t7 30ms t8 30ms powerMod LED Indicator The LED indicator on each powerMod module gives a visual indication of the information contained in the Power Good sign...

Page 11: ...able Using an External Signal A global enable function may be implemented using a signal from the system using the diagram shown This function enables ALL powerMod outputs Temperature Alarm Open colle...

Page 12: ...ator configure html Section 4 11 powerPac Options Reverse Fan Option 02 The UltiMod is available with reverse air flow direction This is ideal to expel air from the system and works particularly well...

Page 13: ...pplies are certified to the latest edition as well as the 1st Edition EN60601 1 Medical Devices Directive The 3rd Edition of this standard is published and all Excelsys medically approved power suppli...

Page 14: ...is not a guarantee of system compliance System EMC performance can be impacted by a number and combination items Design consideration such as PCB layout and tracking cabling arrangements and orientati...

Page 15: ...he relevant standards HALT Highly Accelerated Life Testing Poor reliability low MTBF frequent field returns high in warranty costs and customer dissatisfaction are often the result of design and or pr...