Appendix 3: Analog Communications
The output characteristics of standard modules can also be monitored and controlled with analog signals via the J100x
connectors.
Remote Voltage Setting (Using External Voltage)
Available On:
Standard Modules (CmA-CmD), Bulk Modules (CmE-CmF)
The output voltage of the module can be set by applying a control voltage Vtrim across the Output Signal Connector (J100x)
pins Vtrim (Pin 6) and Common (Pin 1 or Pin 3). The Vtrim voltage required for the users desired output voltage can be
calculated using the following formula.
𝑉
𝑡𝑟𝑖𝑚
=
𝑉
𝑜𝑢𝑡
− 𝐹
𝐾
Where:
Module
F
K
CmA
2.43
1.59
CmB
5.85
3.84
CmC
13.82
6.3
CmD
26.13
13.2
CmE
22.45
1.19
CmF
43.06
0.28
Please note that the upper range of remote trimmable voltage is limited by the potentiometer setting.
Remote Voltage Setting (Using External Resistance)
Available On:
Standard Modules (CmA-CmD), Bulk Modules (CmE-CmF)
The output voltage of the module can be set by placing a resistor R
VTRIM
across the Output Signal Connector pins Vtrim (Pin
6) and Common (Pin 1 or Pin 3). The R
VTRIM
resistance required for the users desired output voltage can be calculated using
the following formula.