Preparations: 

1.  Determine and mark the center line on the ceiling where the range hood will be installed. 

Make sure there is proper clearance within the ceiling or wall for exhaust vent. 

2.  Due  to  the  weight  and  size  of  this  unit,  please  make  sure  that  the  support  system  or 

framework being used is stable and secure in the ceiling. 

3.  Put a thick, protective covering over counter top, cook top or range to protect from damage 

or dirt. Remove any hazardous objects around the area when installing. 

4.  Mark the locations of the support mounting bracket holes, vent cutout (if used) and power 

supply cable cutout on the ceiling. Use drill and saber saw or keyhole saw to cut openings 

for power supply cable and vent (see Venting requirements and Electrical requirements) 

5.  If  venting  to  the  outside  install  vent  system  (See  Venting  Requirements,  Page  3).  Use 

caulking to seal exterior wall or roof openings. 

6.  Disconnect main electrical supply, prepare and run electrical wiring through ceiling. Leave 

approximately  12”  of  electrical  cord  hanging  from  the  ceiling.  Do  not  restore  power  until 
wiring is completed. 

7.  Disconnect power cord, remove the aluminum filter by pressing on the latch and gently pull 

the baffle filter down. 

8.  Set aside the aluminum filters until the range hood is properly installed. 

 

 

 

 

 

Turn On: 

Press the speed controls witch to select the desired level of power .Once button is pressed, the 

previous speed mode will cancel. 

Press the Light Switch to power on the lights. 

 

Turn Off: 

Press the Power Switch to turn off the power. 

Press the Light Switch to power off the lights. 

 

 

 

 

 

             

1.If the range hood does not operate after installation:   

Check if the range hood has been plugged in, make sure that all power has been turned on and 

all electrical wiring are properly connected. 

Swap out light assembly to working ones to determine whether it is caused by defective bulbs 

(See Replacing the light bulbs) 

2.The range hood vibrates when the blower is on: 

The range hood might not have been secured properly on to the ceiling) 

Troubleshooting 

Range Hood Operations 

Summary of Contents for CXW B1208

Page 1: ...ngehood CXW B1208 CXW B1480 Instruction and Installation Manual IMPORTANT Read and save these instructions NOTICE Installer Leave this guide with the homeowner Homeowner Keep this guide for future ref...

Page 2: ...agent or similarly qualified persons in order to avoid a hazard there shall be adequate ventilation of the room when the range hood is used at the same time as appliances burning gas or other fuels At...

Page 3: ...h as those published by Energy Safe Australia and the local authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always...

Page 4: ...n frying oil in the pan can easily overheat and catch fire The risk of self combustion is higher when the oil has been used several times 5 NEVER cook on open flames under the range hood 6 Cleaning Th...

Page 5: ...ures before installation 1 Distance from the floor to the ceiling 2 Distance between the cooking surface to the range hood 3 Height of hood and duct cover For the most efficient and quiet operation 1...

Page 6: ...e duct size from 150 mm to 200 mm If a reducer is used install a long reducer instead of a pancake reducer Reducing duct size will restrict airflow and decrease airflow thus reduce duct size as far aw...

Page 7: ...elbow is needed IMPORTANT NEVER exhaust air or terminate duct work into spaces between walls crawl spaces ceiling attics or garages All exhaust must be individually ducted to the outside Use metal alu...

Page 8: ...should be connected directly to the fused disconnect or circuit breaker box through flexible armored or non metallic sheathed copper cable Do not use extension cord or adapter plug with this appliance...

Page 9: ...upply prepare and run electrical wiring through ceiling Leave approximately 12 of electrical cord hanging from the ceiling Do not restore power until wiring is completed 7 Disconnect power cord remove...

Page 10: ...itch power off at service panel and lock switch power off from being switched on accidentally When the service disconnecting means cannot blocked securely fasten prominent warming device such as a tag...

Page 11: ...0 4 to 35 7 0 Lowest to highest Speed Motor Type Double Chamber Ultra Quiet Illumination LED Venting Size 3 X 150mm Round WARRANTY TERMS AND CONDITIONS The Excelsior Range Hood is covered by a 24 mon...