Page 1: ...ngehood CXW B1208 CXW B1480 Instruction and Installation Manual IMPORTANT Read and save these instructions NOTICE Installer Leave this guide with the homeowner Homeowner Keep this guide for future ref...

Page 2: ...agent or similarly qualified persons in order to avoid a hazard there shall be adequate ventilation of the room when the range hood is used at the same time as appliances burning gas or other fuels At...

Page 3: ...h as those published by Energy Safe Australia and the local authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always...

Page 4: ...n frying oil in the pan can easily overheat and catch fire The risk of self combustion is higher when the oil has been used several times 5 NEVER cook on open flames under the range hood 6 Cleaning Th...

Page 5: ...ures before installation 1 Distance from the floor to the ceiling 2 Distance between the cooking surface to the range hood 3 Height of hood and duct cover For the most efficient and quiet operation 1...

Page 6: ...e duct size from 150 mm to 200 mm If a reducer is used install a long reducer instead of a pancake reducer Reducing duct size will restrict airflow and decrease airflow thus reduce duct size as far aw...

Page 7: ...elbow is needed IMPORTANT NEVER exhaust air or terminate duct work into spaces between walls crawl spaces ceiling attics or garages All exhaust must be individually ducted to the outside Use metal alu...

Page 8: ...should be connected directly to the fused disconnect or circuit breaker box through flexible armored or non metallic sheathed copper cable Do not use extension cord or adapter plug with this appliance...

Page 9: ...upply prepare and run electrical wiring through ceiling Leave approximately 12 of electrical cord hanging from the ceiling Do not restore power until wiring is completed 7 Disconnect power cord remove...

Page 10: ...itch power off at service panel and lock switch power off from being switched on accidentally When the service disconnecting means cannot blocked securely fasten prominent warming device such as a tag...

Page 11: ...0 4 to 35 7 0 Lowest to highest Speed Motor Type Double Chamber Ultra Quiet Illumination LED Venting Size 3 X 150mm Round WARRANTY TERMS AND CONDITIONS The Excelsior Range Hood is covered by a 24 mon...