Excell ESW User Manual Download Page 7

 

                                                                                            

               

 

 
EXCELL PRECISION CO., LTD.     

02005311  

ZSME3000000272 

.

.

   

.

.

   

.

   

.

.

   

.

   

.

   

.

P c s

 

1-2 Power Supply 

 

 

Power Supply Selection 

 
1. 

DC

   

6V / 4Ah rechargeable battery

 

2. 

AC 110V~240V (±10

) adapter 

 

Power Consumption 

 
14mA (system no backlight

Single display)                               about 275 hours 

19mA (system backlight

single display)                                     about 200 hours 

 

Low Battery Warning 

   
Please note when the (         ) symbol keeps flashing on the display, the batteries should 
be changed. 

 

  The scale will turn off automatically after a few hours when the low battery warning 

symbol shows up. The scale must be fully charged, before operating again. 

 

1-3 Panel and Keyboard Introduction 

 

 

 

Icon Introduction 

                      
STABLE 

:

 The weight is stable. 

GROSS 

:

 The scale is in the gross mode.  The display shows the goods and any 

container weight.  This Gross status indication is on when the TARE 
function is used. 

    

:

 The unit weight is not sufficient.  When the icon is on, the counting 

function is operational but the count may contain errors. 

    
 

:

 The sampling size is not sufficient When the icon is on, the counting 

function is operational but the count may contain errors. 

 
Keyboard Function 

 

 ON/ZERO  KEY 

This key possesses two functions: Power On and Zero function. 

 

 OFF  KEY 

When the scale is switched on, press the  

OFF

  key, the scale will switch off. 

 

 TARE  KEY 

The tare function will not operate during the following conditions: 
 

Summary of Contents for ESW

Page 1: ...rein is the property of Excell Precision Limited and is supplied without liability for errors or omissions No part may be reproduced or used except as authorized by contract or other written permissio...

Page 2: ......

Page 3: ...8 1 7 WEIGHT UNIT 8 CHAPTER 2 ADVANCED FUNCTIONS 9 2 1 ADVANCED FUNCTION SETTING TABLE 9 2 2 ADVANCED FUNCTION SETTING WORKFLOW 10 2 3 GENERAL FUNCTION SETTING 11 2 3 1 Automatic Backlight Function Se...

Page 4: ...of any kind 3 If possible avoid connecting the scale to ac power outlet sockets which are adjacent to other appliances to minimise the possibility of interference affecting the performance of the sca...

Page 5: ...de 3 Do not short the battery terminals to check whether there is current Please check whether the connection point is firm to guarantee good connection 4 The battery should be replaced by specialized...

Page 6: ...hortens the weighing operation duration Selectable units Kilogram kg gram g ounce oz and pound lb weighing units available Built in rechargeable battery can be easily replaced Low power indication and...

Page 7: ...gain 1 3 Panel and Keyboard Introduction Icon Introduction STABLE The weight is stable GROSS The scale is in the gross mode The display shows the goods and any container weight This Gross status indic...

Page 8: ...ght units the icons or arrows will indicate the active units as appropriate The units available are dependent on the exact scale model After power off the scale will memorize the active units When the...

Page 9: ...r the arrow pointing to the icon will be on When the or are indicated the scale is still operational but the count may contain errors To power off in this mode the scale will memorize the Pcs unit Whe...

Page 10: ...0 002204623 lb lb oz 1 g 0 03527396 oz INTERNAL VALUE MODE must hook up Load Cell to test c Press TARE to enter and the display shows internal value d Please check whether the internal value has chang...

Page 11: ...LAY LEVEL 1 FUNCTION DISPLAY LEVEL 2 FUNCTIONS Exit the ADVANCED FUNCTION setting mode Return to theADVANCED FUNCTION setting menu Automatic backlight function setting Automatic power off timer settin...

Page 12: ...The LCD shows Overall workflow of the Advanced Function setting mode General Function setting mode External Weight Calibration Reserved Exit the Advanced Function setting mode Refer to the following...

Page 13: ...c Power off Timer Settings Hi Lo OK Settings Restore the Default Settings Noise Filter Settings Hold Function Settings Auto Unit Weight Averaging Setting Refer to the following sections for detailed o...

Page 14: ...t function When the weight is over 10d the display backlight will be on After the weight is stable for 10 seconds or when the scale returns to zero the display backlight switches off DISPLAY ACTIONS N...

Page 15: ...Timer Setting Select in the General Function setting mode to change the automatic power off timer setting LCD displays the last status Automatic power off function When the weight on weigh pan is les...

Page 16: ...esired low limit value Press TARE key Key in the parameter setting for alarm Press TARE key LCD displays the last status LCD displays the last status Alarm setting a b c The definition of a b c positi...

Page 17: ...4 Sampling setting for the counting function For OIML NTEP or Sri Lanka approved models setting is disabled ACTIONS DISPLAY NOTE Return Cancel the restoration Restore to the default setting Press TARE...

Page 18: ...etting Use ON ZERO or UNITS keys to key in the parameters Default setting 5 Parameter 0 9 the larger the number the faster the filter response Fast response can lead to weight instability Digital swit...

Page 19: ...weight is continually changing To exit this mode press any key Stable hold 1 mode When the weight is stable the LCD shows the current weight value To exit this mode press any key Stable hold 2 mode W...

Page 20: ...or UNITS keys to key in the parameters Default setting 0 0 Auto unit weight averaging 1 Non auto unit weight averaging ON ZERO key Upward key from 0 to 9 UNITS key Downward key from 9 to 0 TARE key M...

Page 21: ...e maximum capacity of 1st unit and the unit The digit on the right side keeps flashing The scale is calculating the internal value of the zero point After stabilization the LCD shows the calibration w...

Page 22: ...CO LTD 02005311 ZSME3000000272 Appendix 1 7 Segment Display Characters Digit 7 segments letter Alphabet 7 segments letter Alphabet 7 segments letter 0 A N 1 B O 2 C P 3 D Q 4 E R 5 F S 6 G T 7 H U 8 I...

Reviews: