background image

  

EXCELL PRECISION CO., LTD

.     

                               

 

Counting                                                                                                                                          ZSME200000003 

36 

CHAPTER 5 INTERFACE 

4

   

Function available for RS232 or PRINTER output, please refer to section 7 and 8 

below. 

5-1 TOTALISING 

Œ

 

Press the

 

 

Z

 

 

key until the unit weight displays

 

 

 

 

 

  followed by 

pressing key

 

  1 

 

           

WEIGHT

 

     

UNIT WEIGHT

 

QUANTITY

 

- - - - -   

 

 

 

 

 

 

 

- - - - - - 

 
 
 

           

WEIGHT

 

     

UNIT WEIGHT

 

QUANTITY

 

 

 

 

 

 

 

 

 

 
 

 

Press the 

  1 

 

key.

   

           

WEIGHT

 

     

UNIT WEIGHT

 

QUANTITY

 

 

 

 

 

 

 

 

 

 

 

 

 

            Use the number    0 ,    1    or    2    key to select 0, 1, or 2 

 

 

   

Press

 

 

M+

 

 

key and the window display will show the totalised value.     

  After 3 seconds, the scale will return to counting mode.   

 

   

Press

 

 

M+

 

 

key and the window display will show the totalised value.   

  Press

 

 

CE

 

 

key and the scale will return to counting mode. 

 

   

Press

 

 

M+

 

 

key and the display window will not show the totalised   

  value as the buzzer will beep.

 

 

Press the

   

.

   

key to exit the setting mode and the scale will return to counting mode. 

Summary of Contents for Counting Scale

Page 1: ...ained herein is the property of Excell Precision Limited and is supplied without liability for errors or omissions No part may be reproduced or used except as authorised by contract or other written p...

Page 2: ......

Page 3: ...ht of Object is Known 14 2 9 DEDUCTION OF CONTAINER WEIGHT 15 2 9 1 The Weight of Container is Unknown Tare 15 2 9 2 Clear Tare Value 15 2 9 3 The Weight Container is Known Pre set Tare 16 2 9 4 Clear...

Page 4: ...Weight Preset 31 4 4 COMBINATION TYPE DUAL WEIGHING UNIT UNIT WEIGHT PRESET 32 4 4 1 Unit Selection 32 4 4 2 Unit Weight Preset Stores 33 4 4 3 Quantity Preset 34 4 4 4 Weight Preset 35 CHAPTER 5 INTE...

Page 5: ...e free from vibrations for accurate weight readings 2 Adjust the four levelling feet to set the scale pan level using the spirit level bubble located at the front of the scale 3 Avoid operating the sc...

Page 6: ...container weight 2 0 or Zero Zero indication 3 or M M Totaliser 4 Stable or Stable indication 5 If the piece weight is smaller than Minimum Sampling Weight 3 will be displayed In order to clear the sy...

Page 7: ...EXCELL PRECISION CO LTD Counting ZSME200000003 5 d division...

Page 8: ...DITIONAL FUNCTIONS TYPE I Dual Weighing Unit 7 8 9 SMPL Q TY PST 4 5 6 UNIT W T lb kg 1 2 3 Z M 0 CE T MC 7 8 9 4 5 6 lb kg 1 2 3 0 CE This is a CLEAR key to delete all the High Limit values Please re...

Page 9: ...ONS TYPE II Unit Weight Preset 7 8 9 SMPL Q TY PST 4 5 6 UNIT W T U W PST 1 2 3 Z M 0 CE T MC 7 8 9 4 5 6 U W PST 1 2 3 0 CE This key selects 10 pre set stores of piece weight Please refer to page 24...

Page 10: ...PL Q TY PST 4 5 6 UNIT W T U W PST 1 2 3 Z M 0 CE T MC 7 8 9 4 5 6 U W PST 1 2 3 0 CE This is a dual function key which selects Preset piece weight stores and weighing units selection Please refer to...

Page 11: ...adapter Power Consumption Approximately DC 20 mA Approximately DC 40 mA With display Backlight Low Power Warning When the symbol is displayed it indicates that the scale needs to be recharged or the d...

Page 12: ...ch towards the position 2 3 DISPLAY BACKLIGHT AUTO BACKLIGHT Press Z key the unit weight displays followed by pressing 5 When the weight is over 10 divisions or any key is pressed the display backligh...

Page 13: ...itions other unstable environments a useful additional facility is available With the zero display mask it is possible to configure the scale not to show the first division of the weight When configur...

Page 14: ...place the weight on the scale when the reading is stable the scale will automatically calibrate While the scale is counting back to zero remove all the weights from the scale The Calibration procedur...

Page 15: ...is 2 5g If the next batch of product of the same type has a slightly different unit weight say 2 8g then because the difference between the to unit weights is greater than 10 the scale will average t...

Page 16: ...y display will flash for about 3 seconds whilst it is flashing press the SMPL key to complete the sampling routine Otherwise the number entered and displayed by the unit weight display will be used as...

Page 17: ...st piece weight value 2 9 DEDUCTION OF CONTAINER WEIGHT 2 9 1 The Weight of Container is Unknown Tare Place the container onto the scale Container Weight Press T Key Once the scale stabilizes it will...

Page 18: ...ress T key 0 3 Stable 3 Enter the weight value of the container 0 3 Stable 3 Weight entered Press T key 3 Stable 3 The User mode function to operate the Pre set tare is to set 1 The scale can perform...

Page 19: ...9 4 Clear The Pretare Value When the container is removed from the scale the weight display will show a negative sign Press the T key to clear pre tare value and the weight display will reset to zero...

Page 20: ...to six digits maximum 2 10 1 Quantity totalising Place a desired object onto the scale Object Weight Unit Weight Object Q ty Placed on Scale Press M Key Once the scale is stable M 3 Stable 3 Total Wei...

Page 21: ...Totalising With the unit weight display showing zero place an object onto the scale Object Weight Press M key Once the scale has stabilized M 3 Stable 3 Total Weight totalised Total Number of addition...

Page 22: ...d Values Press the MC key to clear all of the totalised values and the 3 symbol adjacent to the M icon on the overlay will switch off The totals for weight number of additions and quantity are all cle...

Page 23: ...ay will show the totalised value Then the scale will count back to zero when the CE key is pressed 2 When M key is pressed the beeper only will sound and the display won t show the totalised value To...

Page 24: ...the scale only when the weight is stable 1 The quantity will be accepted by the scale even if the weight is un stable To exit and save the entry press the key 3 4 M OPERATION Press Z then 1 followed...

Page 25: ...the entry press the key 3 6 MULTIPLE UAGE KEY U W PST kg lb FUNCTION SELECTION Press Z then 1 followed by 6 Weight Unit Weight Quantity X Press 0 or 1 to select the required mode 0 Momentary press of...

Page 26: ...EXCELL PRECISION CO LTD Counting ZSME200000003 24 the scale...

Page 27: ...Press 0 3 to select the required baud 0 1200 1 2400 2 4800 3 9600 To exit and save the entry press the key Transmit mode Press Z then 1 followed by 8 Weight Unit Weight Quantity X Press 0 3 to select...

Page 28: ...larm value set Set the Hi Limit alarm value for Quantity Preset Method 1 Place the sample object onto the weigh pan and increase the number of items gradually until the quantity reaches the desired Hi...

Page 29: ...The scale will make a warning beep and the unit weight window will display a blinking if the quantity is over the Hi limit alarm value set Set the Hi Limit value for Quantity Preset Press Q TY PST ke...

Page 30: ...3 Stable 3 Latest Preset Value Enter a desired Hi Limit value Use CE key to correct the value entered 0 3 Stable 3 Hi Limit Value Entered 4 The unit and the decimal points for the high limit value en...

Page 31: ...d and the display will show the unit weight previously saved in that store Set Unit Weight Preset Use the number 0 9 to enter the unit weight value 0 3 Stable 3 Press U W PST key 0 3 Stable 3 Press U...

Page 32: ...s over the Hi limit alarm value set Hi Limit Value for Quantity Preset Press Q TY PST key whether the scale has object on the weigh pan or not 0 3 Stable 3 Latest Preset Value Enter a desired Hi Limit...

Page 33: ...0 3 Stable 3 Latest Preset Value Enter a desired Hi Limit value Use CE key to correct the value entered 0 3 Stable 3 Hi Limit Value Entered 4 The unit and the decimal points for the high limit value...

Page 34: ...y function press the combination key for about 3 seconds and the display will show the following 0 3 Stable 3 Use the number 1 or 2 key to select 1 or 2 Remarks 1 First unit 2 Second unit The scale wi...

Page 35: ...press the combination key for about 3 seconds and the display will show the following 0 3 Stable 3 Press the combination key If the unit weight preset setting is a secondary function press the combin...

Page 36: ...er the Hi limit alarm value set Set the Hi Limit Value for Quantity Preset Press Q TY PST key whether the scale has object on the weigh pan or not 0 3 Stable 3 Latest Preset Value Enter a desired Hi L...

Page 37: ...3 Stable 3 Latest Preset Value Enter a desired Hi Limit value Use CE key to correct the value entered 0 3 Stable 3 Hi Limit Value Entered 4 The unit and the decimal points for the high limit value en...

Page 38: ...the 1 key WEIGHT UNIT WEIGHT QUANTITY X Use the number 0 1 or 2 key to select 0 1 or 2 0 Press M key and the window display will show the totalised value After 3 seconds the scale will return to count...

Page 39: ...IT WEIGHT QUANTITY WEIGHT UNIT WEIGHT QUANTITY Press the 2 key WEIGHT UNIT WEIGHT QUANTITY X Use the number keys 0 or 1 key to select 0 or 1 0 Preset tare is not allowed if there is a weight on the sc...

Page 40: ...HT UNIT WEIGHT QUANTITY WEIGHT UNIT WEIGHT QUANTITY Press the 3 key WEIGHT UNIT WEIGHT QUANTITY X Use the number keys 0 or 1 to select 0 or 1 0 The Q TY PST will only operate when the weight is stable...

Page 41: ...WEIGHT QUANTITY WEIGHT UNIT WEIGHT QUANTITY Press the 4 key WEIGHT UNIT WEIGHT QUANTITY X Use the number keys 0 or 1 to select 0 or 1 0 Totalising will only be carried out when the weight is stable 1...

Page 42: ...UNIT WEIGHT QUANTITY WEIGHT UNIT WEIGHT QUANTITY Press the 5 key WEIGHT UNIT WEIGHT QUANTITY X Use the number keys 0 or 1 to select 0 or 1 0 The weight needs to return to zero before the next totalis...

Page 43: ...NTITY X Use the number keys 0 or 1 to select 0 or 1 0 Press the Unit Selection function key main function and hold it down for 3 seconds the function of the key becomes Unit Weight Selection secondary...

Page 44: ...ess 1 WEIGHT UNIT WEIGHT QUANTITY WEIGHT UNIT WEIGHT QUANTITY Press the 7 key WEIGHT UNIT WEIGHT QUANTITY X Use number keys 0 to 3 key to select 0 1200 1 2400 2 4800 3 9600 Once the setting is done re...

Page 45: ...ey to transmit 2 Stable transmit 1 Stream transmit 3 EZ 2 printer only Once the setting is done re start the scale by turning the power off on Press the key to exit the setting mode and the scale will...

Page 46: ...EXCELL PRECISION CO LTD Counting ZSME200000003 44 NO No of totalising operations N W Net Weight U W Unit Weight PCS Piece T N Total no of totalising operations T W Total Weight T A Total Amount...

Reviews: