Excell AWH3 User Manual Download Page 3

EXCELL PRECISION CO., LTD.

 

 

 

 

0201813X                                   

 

                                                     

   

   

         

                            ZSME300000366

                     

 
 
 
 
 
 
 
 
 
 
 

Preparing to Use the Scale 

1.  Locate the scale on a firm level surface free from vibrations for accurate weight readings. 

Adjust the four leveling feet to centre the leveling bubble on the scale. 

2.  Avoid hot sunshine directly on the scale or near the exhaust port of

 

ventilating system. 

3.  Please use a separate power source plug to avoid the disturbance of other electric 

appliances. 

4.  There should be no weight on the scale when power is turned on. 

5.  Commodity should be placed at the centre of platter when being weighed, and its size should 

not exceed the dimension of the platter. 

6.  Please warm the scale 15 ~ 20 minutes before using. 

7.  Please note that when 

  symbol appears on the screen, the scale needs to be charged. 

8.  Any suggestion is warmly welcome.   

 

Precautions for Use 

1.  Please  operate  or  charge  the  scale  in  an  open  area.  Do  not  squeeze  the  power  cord  to 

avoid wire on fire. 

2.  Please keep scale in a cool and dry place. Do not store under high temperatures.   

3.  Please keep the scale clean and free from insect infestation. 

4.  Avoid  impacting  with  other  items  or  overloaded  with  excessively

 

heavy  weights  (The  load 

must not exceed the maximum capacity of the

 

scale). 

5.  If the scale is not going to be used for some time, please clean it and store it in a plastic bag 

in dry condition. A desiccant sachet may be included to prevent moisture from building up. 

6.  Operating temperature: -10

 ~ + 40

 

7.  It is recommended to be used indoors and in environments with a height of less than 2000m 

8.  If the product is used in a manner not specified by the manufacturer, product warranty may 

be limited.

 

Thank  for  your  purchasing  of  our  EXCELL  Weighing 
Scale. To guide you to use our product correctly, please 
read  this  User  Manual  carefully  to  extend  the  life  of 
machine and to avoid error. 

 

Summary of Contents for AWH3

Page 1: ...n is the property of EXCELL PRECISION CO LTD and is supplied without liability for errors or omissions No part may be reproduced or used except as authorized by contract or other written permission Th...

Page 2: ...NOT AVAILABLE IN 4 5 KEY MODELS 10 2 3 1 Sampling 10 2 3 2 Check Weighing 11 2 3 3 Totalizing 11 CHAPTER 3 GENERAL FUNCTION SETTING 11 3 1 F4 CHECK WEIGHING CONFIGURATIONS 12 3 2 F5 RS 232 OUTPUT SET...

Page 3: ...utions for Use 1 Please operate or charge the scale in an open area Do not squeeze the power cord to avoid wire on fire 2 Please keep scale in a cool and dry place Do not store under high temperatures...

Page 4: ...3 Do not short the battery terminals to check whether there is current Please check whether the connection point is firm to guarantee good connection 4 The battery should be replaced by specialized p...

Page 5: ...cale 4 Check Weighing function for high limit and low limit and OK range 5 5 HOLD functions including animal scale HOLD 6 Depending on actual space a RS232 card and or a relay card can be installed 1...

Page 6: ...ity for weight check or quantity check TGT SET Accumulate weight or quantity Tare to deduct the container weight TARE Set preset tare Recall the totalization value preset value and pre tare value RE C...

Page 7: ...weight accuracy 1 5 Error Messages oL Weight exceeds 9d of maximum capacity d division E1 Zero value after power on is over 10 FS E2 Zero value after power on is less than 10 FS E4 Unstable zero retur...

Page 8: ...When the weight of the container is unknown Place the container on the platter after stable and press key the weight value returns to zero and net indication is on Place goods into the container then...

Page 9: ...r gross value In tare mode key is able to work When it displays all keys are disable except 2 2 5 Check Weighing Mode 4 5 key models need to set through F4 1 Preset High limit Low limit and Beeper val...

Page 10: ...xed as follows When over Low Limit the beeper beeps and is off Whether stable or not the beeper beeps and LCD indication is on Warning device setting not available in 4 5 key models Set HI value and v...

Page 11: ...Refer to F5 setting 2 Clear Totalized Weight Values not available in 4 5 key models Press then key to clear all totalized weight values When changing between weighing and counting mode or selecting we...

Page 12: ...ting down to zero press and hold key until the display shows the software version number 02018 Release the key the scale enters into the configuration setting mode and display F0 key upward key key do...

Page 13: ...table the beeper beeps and the indications are on 1 After stable the beeper beeps whether stable or not the indications are on 2 whether stable or not the beeper beeps and the indications are on 3 ope...

Page 14: ...zed complete format r n P 5 Stable transmission in totalizing mode Same format as r n P 3 r n P 6 Press key to transmit simple free format Please refer to F14 r n P 7 Press key to transmit complete Fr...

Page 15: ...I 0 0 0 1 0 0 CR LF Set high limit N G CR LF over max weight N D CR LF Increment d is incorrect 1 1 b CR LF Set buzzer 1 1 b CR LF successful Stable transmission r n P 1 Continuous r n P 2 Press key...

Page 16: ...d simple format r n P 3 S N WT UNIT kg lb 0001 1 0000 Press or key 0002 1 0000 Press or key 0003 1 0000 Press or key 0004 1 0000 Press or key 0005 1 0000 Press or key 0005 5 0000 Press twice to print...

Page 17: ...e stable Weight zero point Weight 20 weighing units i e 5 x Weight 1 weighing unit Beeper beeps twice and printing data stable weight compliant with conditions on the left is ready to be sent 2 Just r...

Page 18: ...ansmit when weight change 10d Transmit when weight change 10d Print TOTAL and clears totalized values r n p 4 Press key to transmit totalized complete format Transmit when weight change 10d Transmit w...

Page 19: ...value is transmitted After return to zero transmit next stable weight s weight value only r n p 15 Enter serial number reply serial number weight Enter serial number and put the weight on Once it is s...

Page 20: ...e press any key except the key hold 3 After the scale is stabilized the scale will automatically hold the display value not changeable due to external variables After zero return or weight is less tha...

Page 21: ...and scale enters hold mode This whole hold mode entry and exit process will repeat continuously 3 6 F11 ID Code Setting must be used with r n P 1 r n P 2 r n P 8 of F5 Press key or key to select F11...

Page 22: ...ress key Print key setting Use and to set 0 2 Default setting 0 P r F 0 If weight variation is beyond 1d 10d key print totalized weight Otherwise print current weight d division P r F 1 key print curr...

Page 23: ...nds to setup 1 second 0 0 0 0 0 0 Use key to enter 12 digit Part number 0 0 0 0 0 0 1 second 0 0 0 0 0 0 Use key to enter 10 digit Serial number 0 0 0 0 After power off S N will reset as 1 P N will be...

Page 24: ...to get in checkweighing mode to set the HIGH and LOW limit points Between HIGH and LOW limits are OK range If the weight is below LOW limit the data will output in LOW port If the weight is between H...

Page 25: ...5 J1 J2 SHORT 4 Configuration OK High and Low can be set to NO normally open Type A or NC normally closed Type B The default value is NO normally open Type A OK High and Low are NO normally open Type...

Page 26: ...Code 01 Read Function Code 05 and 15 Write Modbus SCALE Modbus SCALE Output Modbus SCALE Input 40004 40005 As display value 00000 Stable status 01000 Zero 00001 Zero status 01001 Function Code 06 and...

Page 27: ...dbus SCALE Modbus SCALE Output Modbus SCALE Input 40005 40006 As display value 00001 Stable status 01001 Zero 00002 Zero status 01002 Function Code 06 and 16 Write 00003 Gross 01003 Tare 41001 41002 P...

Page 28: ......

Reviews: