Excelitas Technologies X-Cite XYLIS XT700 Series User Manual Download Page 1

 

 
 
 
 
 
 
 
 
 
 
 
 

X-Cite

®

 XYLIS User Guide  

Applies to XT700 Series Models: 

 

XT720S 

 

XT720L 
 

 

 

 
 

 

 

 

Summary of Contents for X-Cite XYLIS XT700 Series

Page 1: ...X Cite XYLIS User Guide Applies to XT700 Series Models XT720S XT720L...

Page 2: ...ans without the prior written consent of Excelitas Canada Inc Every effort has been made to ensure information in this manual is accurate however information in this manual is subject to change withou...

Page 3: ...Service Data 16 5 Operation External Control 17 5 1 USB RS 232 17 5 1 1 Driver Installation via internet 17 5 1 2 Driver Installation via ZIP file 18 5 1 3 Verify Installation Get COM Port Number 18...

Page 4: ...2 10 1 Warranty Terms 32 10 2 Returning equipment to Excelitas 33 11 Contact Information 33 11 1 General 33 11 2 Technical Support and Service 33 11 3 Accessories and Replacement Parts 33 Table of Fig...

Page 5: ...e their location or behavior Excelitas Technologies Corp is a global technology leader focused on delivering innovative customized solutions to meet the lighting detection and other high performance t...

Page 6: ...laser product Input Output Signals Input Signal CAUTION Hot surface 2 2 Safety Precautions Please observe the following safety precautions at all times during operation and maintenance of this produc...

Page 7: ...onitoring the unit during manual operation The level of UV and visible energy supplied by this product is sufficient to ignite flammable substances During manual operation the unit must be attended at...

Page 8: ...ordered 5 Foot Pedal if ordered 6 Accessories Box containing a Quick Start Instruction Sheet user guide software and driver downloads are available on the Excelitas website www excelitas com Pages Pro...

Page 9: ...Guide 035 00683R Rev1 Figure 2 Front and Rear Panel Connections Figure 3 SpeedDIAL 3 2 Installation Set up 1 Unpack a Carefully unpack the unit and accessories from the shipping carton Rotating Dial...

Page 10: ...tting hold the adaptor firmly against the light port and twist the collar to lock the components together iv Olympus Tighten the hex fastener s with the 3mm Hex Tool Depending on the model there may b...

Page 11: ...mmended clearance is 20cm 8 inches c Note that the main power switch is located on the front panel of the unit The unit should be placed so that the switch is convenient for the operator to access 5 C...

Page 12: ...Basics 1 Start the unit a Flip the rocker switch on front of the main unit to turn X Cite system on b The system will have a brief initialization period approximately 5 seconds The speedDIAL display...

Page 13: ...ings and control options To access the main menu press and hold the dial for one 1 second To navigate the menus turn the dial to scroll through the options An arrowhead will indicate the currently sel...

Page 14: ...ut i Select Dim and scroll through the time out options which are Off and 1 thru 999 seconds in 1 second increments Off will turn off the backlight timer i e backlight will always be on ii Click dial...

Page 15: ...sired setting On will enable i e double click speedDIAL Favorite setting Off will disable i e double click speedDIAL do nothing ii Click dial to save selection and return to Favo menu d To adjust the...

Page 16: ...id confusion it recommended to change settings with the LEDs turned off 4 3 6 Hand Display Screen Orientation In this menu the LCD orientation can be rotated 180 This allows operators to use speedDIAL...

Page 17: ...the X Cite will appear as a COM port in Device Manager and is functional as a COM port for programming purposes This is done for legacy program support and ease of integration A virtual COM port driv...

Page 18: ...or another easily accessible location d Power on X Cite unit e The new hardware found wizard will appear Select No to search Windows update for the software Click Next to continue f Select Install fro...

Page 19: ...ious section by extracting and saving the files into a folder on desktop or another easily accessible location c To begin installation go to unzipped files from step b double click on setup exe or set...

Page 20: ...ngaged and or not available v If icons are ALL grey X Cite unit is not connected and or turned off Figure 7 X Cite Control Panel ICON NAME DESCRIPTION Alarm Green All OK Red Alarm on Click will clear...

Page 21: ...oftware packages if requested specify the serial port parameters as 19 200 baud no parity 8 data bits and 1 stop bit c When controlling this X Cite unit some commercial software packages may block man...

Page 22: ...n this always active state the system continues to consume energy and mechanical components accumulate wear To help minimize unnecessary consumption at the end of an imaging session or if equipment is...

Page 23: ...Rev1 5 2 3 TTL Signal and LED Status TTL LED Status High ON Low OFF 5 2 4 TTL Input Specifications a Connector type BNC female port b Maximum low level 0 8V c Minimum high level 2 2V d Maximum high le...

Page 24: ...w minimum operating temperature Ensure the room temperature is within the recommended operating limits If unit has been stored transported in a cold environment allow it to warm up to room temperature...

Page 25: ...ve the fuse from the tray and check with a multi meter set to resistance An intact fuse will read 0 or another very low value an open fuse will have an extremely high reading d Note Fuses that chronic...

Page 26: ...tom Action speedDIAL Favorite intensity setting double click turns off LED instead of going to the stored setting Increase delay in the speed Spd setting Ensure Favorite mode is enabled New settings a...

Page 27: ...aning 2 Use a damp cloth only do not allow cleaning solution to get into I O ports air vents or seams 3 Avoid optical surfaces 4 Allow the unit to dry before turning it on 7 3 Cleaning Optical Surface...

Page 28: ...nd Safety Advisor for proper handling storage and disposal instructions 8 Technical Specifications 8 1 General Main Unit speedDIAL Height 260mm 10 3 59mm 2 3 Width 120mm 4 7 a 80mm 3 1 Depth 260mm 10...

Page 29: ...ED and report status on off intensity adjustment system error etc TTL IN BNC External trigger to turn LED on off USB IN OUT B Communication between computer and X Cite unit to control LED and report s...

Page 30: ...19 EU WEEE Directive Council Directive 2011 65 EU RoHS 9 3 FCC FCC Class A Digital Device or Peripheral Information to User NOTE This equipment has been tested and found to comply with the limits for...

Page 31: ...es that could impact health and the environment In order to avoid the dissemination of those substances in our environment and to diminish the pressure on the natural resources we encourage you to use...

Page 32: ...ing neglect by the use of force or in the case of interventions and repairs not carried out by an Excelitas Service Center the guarantee ceases to be valid This guarantee may not form the basis for an...

Page 33: ...ginal packaging if possible 11 Contact Information 11 1 General Excelitas Canada Inc Tel 905 821 2600 Fax 905 821 2055 Toll Free 1 800 668 8752 USA and Canada x cite excelitas com http www excelitas c...

Reviews: