Using the Foot Pedal 

The foot pedal does not disable the Start/Stop button and can be used simultaneously with 
the Start/Stop button on the front panel in any mode or setting. However, the Start/Stop 
button overrides all foot pedal configurations. 
1. Connect the foot pedal to the port that corresponds with the UV LED Head on the back of 
the Controller (refer to Figure 2). 
2. Use the StepCure screen refers to Section 6.3 User Manual 035-00628R to set up the 
exposure parameters and, optionally, to override the default action described below. 
3. Press the foot pedal to trigger an exposure. 

 

Count Up / Count down Mode  

• 

If the arrow in the status bar is pointing up, the unit is in count up mode. The UV LED 
Head connected to channel 1-4 will be on for as long as the foot pedal signal is held low 
or one of the other input control signals is toggled. 

• 

If the arrow in the status bar is pointing down, the unit is in countdown mode. The UV 
LED Head connected to channel 1-4 will be on for the duration of the set timer for that 
channel on the Main Control Panel screen. 

(Note: All LEDs are in either count up or countdown mode) 

 
 
Using the PC Interface with USB Connection 

The LX500 can be commanded via a virtual RS-232 serial port. The serial port communication 
settings are not adhered to and instead communication occurs at the USB 2.0 speed of 
12Mbps. All serial commands are available in an SDK which is available upon request. 
The LX500 complies with the S2000 command set. Use the StepCure screen to select which 
LEDs will respond to this command set. To do this, the first row is the LED #, set the last row to 
PC. Refer to Section 6.3  in User Manual 035-00628R 
 
PLC Signal Descriptions 

 
Refer to User Guide 035-00628R for PLC Signal Description Features. 

 

 
 

REGULATORY 

(refer to user guide for complete details) 

 
Product Safety and Electromagnetic Compatibility 

The OmniCure LX500 Series has been tested and found to comply with product safety and 
electromagnetic compatibility requirements.  For a complete list of tests and for 
certification details, please contact your OmniCure representative or visit: 

https://www.excelitas.com/product-category/omnicure-led-spot-uv-curing-systems-and-
accessories

 

 

CE Marking 

 

 

Council Directive 2014/35/EU 

  Low Voltage Directive 

 

Council Directive 2014/30/EU   

  EMC Directive 

 

Council Directive 2012/19/EU 

  WEEE Directive 

 

Council Directive 2011/65/EU 

  RoHS 

as amended by (EU) 2015/863 

 

       

                               

                           

 

WEEE Directive       

   China RoHS                           FCC 

Reviews: