Kepri™
UV LED Upper-Air System
Excelitas Canada Inc. 2022
All rights reserved
035-xxxxxR, rev.1
7
035-00725R
4
Installation
4.1 Site Inspection
Before you install the device, verify the following:
•
The potential installation location has a minimum ceiling height of 2.7m (9ft).
•
The potential installation location has a nearby installed AC power receptacle easily reachable
with the Excelitas-supplied detachable AC power cord. If there is no nearby accessible outlet,
you may use your own CSA/UL safety approved AC power extension cord under your own
responsibility.
•
The area is free of any elevated flooring which might position a person above the surface used
to determine the minimum ceiling height.
•
Do not install the device in the following locations.
Examples include:
•
Stairways
•
Upper floor balconies
•
Mezzanines
•
Atriums with multiple levels/tiers
•
The area in front of the potential location is free of any artifacts that may obscure the emitted
UV energy.
Do not install the device if items are within 6ft of the front window
; examples include
but are not limited to the following:
•
Sound-deadening material
•
HVAC ductwork
•
Lighting fixtures
•
Electrical or mechanical service conduit
•
Artwork
4.2 Wall Bracket Installation
1.
Position the bottom of the mounting bracket at least 2.3m (90.5”) from the floor (remember the
minimum ceiling height
2. With 6 screws (M4 or #8) secure the mounting bracket to the wall using the appropriate wall
anchors.
Figure 7 Mounting Bracket with Wall Mounting Holes Highlighted
Surface used for
floor-to-bracket
distance
measurement
M4 or #8 screw hole
locations (x6)