background image

Kepri™

 

UV LED Upper-Air System 

 

 

http://www.excelitas.com

 

Excelitas Canada Inc. 2022 

All rights reserved 

035-xxxxxR, rev.1 

5

 

035-00725R 

 

Figure 3  Back View 

 

 

Figure 4  Side View 

 

On/Off 
switch 

AC power 
receptacle 

Array (LED) replacement door 

Summary of Contents for Kepri 010-00490R

Page 1: ...for the following part number Name Type Model Part Numbers Kepri Upper Air System 010 00490R Installation Reference Guide Excelitas Canada Inc 2260 Argentia Road Mississauga ON L5N 6H7 Canada 1 905 82...

Page 2: ...by any means without the prior written consent of Excelitas Canada Inc every effort has been made to ensure information in this manual is accurate however information in this manual is subject to chan...

Page 3: ...Bracket Installation 8 4 4 Securing Kepri to the Mounting Bracket 9 5 Operation 10 5 1 Powering Up 10 5 2 Understanding How the Emissions Work 10 6 Troubleshooting 13 6 1 Failure to Power Up 13 7 Car...

Page 4: ...ure 12 Sensor Detection Areas 11 Figure 13 Location and Removal of Fuse Tray in AC Receptacle 13 Figure 14 LED Replacement Door Removed 15 Figure 15 LED Array Partially Removed 15 Figure 16 LED Replac...

Page 5: ...tation in classrooms hospital rooms office suites and dental offices Kepri s numerous safety features and UL 8802 regulatory approval allow for provide peace of mind operation while its advanced LED t...

Page 6: ...nent the minimum distances between UV generating devices and other objects or surfaces and protection from line of sight exposure to UV radiation in occupied spaces located above the equipment mountin...

Page 7: ...maintenance If servicing the unit turn the device off and disconnect the power source before opening the cover of this unit All cover screws must be replaced prior to applying power to the unit or the...

Page 8: ...ollowing components Kepri upper air unit Kepri wall mount bracket Power cord Carefully unpack the unit and store the packing material for future use If any components are missing or appear damaged ple...

Page 9: ...pper Air System http www excelitas com Excelitas Canada Inc 2022 All rights reserved 035 xxxxxR rev 1 5 035 00725R Figure 3 Back View Figure 4 Side View On Off switch AC power receptacle Array LED rep...

Page 10: ...ill continuously emit UV energy On when Unoccupied The device will only emit UV energy if no motion is detected On when Occupied The device will only emit UV energy if motion is detected Table 1 Emiss...

Page 11: ...Do not install the device in the following locations Examples include Stairways Upper floor balconies Mezzanines Atriums with multiple levels tiers The area in front of the potential location is free...

Page 12: ...size and shape of the pendant 2 Position the bottom of the mounting bracket at least 2 3m 90 5 from the floor Refer to Figure 8 3 Secure the clamping bolts to a pair of slots on the mounting bracket R...

Page 13: ...onding holes Refer to Figure 10 Figure 10 Kepri Module Engaging the Wall Bracket 2 Adjust the module so the bottom of the device is approximately parallel with the floor Refer to Figure 11 Figure 11 K...

Page 14: ...e UV Enable indicator will begin to flash red 7 Set the Emission Selector Switch to the desired setting Refer to Table 1 8 Remove the protective film over the emission window 9 Ensure the area in fron...

Page 15: ...red When motion is detected UV indicator is unlit Table 2 Emission Start and Stop Presence Indicator The Presence detection sensor increases device safety This sensor detects IR radiation from a huma...

Page 16: ...elitas com Excelitas Canada Inc 2022 All rights reserved 035 xxxxxR rev 1 12 035 00725R This feature is not designed to eliminate the exposure risk from entering the UV emission area Before entering t...

Page 17: ...N position Fuse Check Check both main power fuses First disconnect the power cord then carefully remove the fuse tray assembly next to the AC receptacle on the rear of the unit Note Depending on the o...

Page 18: ...chnology The device maintains an internal clock and indicates the percentage of remaining life This is reflected in the color of the Lifetime indicator Lifetime Indicator Color Percentage of Life Rema...

Page 19: ...1 15 035 00725R Figure 14 LED Replacement Door Removed 4 With your fingers remove the LED array Refer to Figure 15 Figure 15 LED Array Partially Removed 5 Insert the replacement array into the device...

Page 20: ...Cleaning of optical surfaces is not generally required However if any visible contamination or fingerprints appear on the lens surface cleaning may be necessary Recommended cleaning materials Compress...

Page 21: ...rate and verify that the optical surface is clean Repeat cleaning steps as necessary 6 Before reinstalling and or using the optics allow them to dry completely CAUTION Before using any solvent consult...

Page 22: ...250VAC Wattage 35W max Table 6 Electrical Specifications 8 3 Electro Optical Parameter Value Peak Emission Wavelength 270nm Optical Output 500mW Emission beam vertical peak 5 5 LED Array lifetime 2 ye...

Page 23: ...35 00725R 8 5 Environmental Transport and Storage Conditions Parameter Value Temperature 35 to 60 C 35 to 140 F Relative Humidity 10 to 95 RH non condensing Atmospheric Pressure 500 to 1060 hPa Table...

Page 24: ...e following effective air exchange ACH data should only be used as a best case guideline Effective Air Exchanges per Hour ACH 4 6 8 10 12 14 16 18 20 ft 2 m 2 100 9 30 150 13 9 200 18 6 250 23 2 300 2...

Page 25: ...a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures FCC FCC Class A Digital Device or Peripheral Information to User NOTE...

Page 26: ...he natural resources we encourage you to use the appropriate take back systems Those systems will reuse or recycle most of the materials of your end life equipment in a sound way The crossed out wheel...

Page 27: ...damage caused by wear and tear careless handling neglect by the use of force or in the case of interventions and repairs not carried out by an Excelitas Technologies Authorized Service Centre the war...

Page 28: ...ps www excelitas com product kepri upper air uvc disinfection system https www excelitas com contact area uvc disinfection light sources Technical support and service 905 821 2600 option 3 1 800 668 8...

Reviews: