background image

 

 
 

OmniCure V3 LED Head  

Assembly Guide & Specifications 

UV LED Head for OmniCure LX500/LX505  

 
 
 
 
 
 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Excelitas Canada Inc. 

2260 Argentia Road 
Mississauga (ON) 
L5N 6H7 Canada 
+1 905.821.2600 
www.excelitas.com 

 

 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

035-00730R Rev 1

 

Summary of Contents for 019-00398R

Page 1: ...Cure V3 LED Head Assembly Guide Specifications UV LED Head for OmniCure LX500 LX505 Excelitas Canada Inc 2260 Argentia Road Mississauga ON L5N 6H7 Canada 1 905 821 2600 www excelitas com 035 00730R Re...

Page 2: ...ference only and are subject to change without notice Printed in Canada Doc No 035 00730R No part of this publication may be reproduced transmitted transcribed stored in a retrieval system or translat...

Page 3: ...y of Symbols 2 2 Components Number Table 4 3 Installation Procedures 5 5 Technical Specifications 6 5 1 Optical Output 6 5 2 Environmental Conditions 10 5 3 Regulatory Compliance 10 5 4 China RoHS 10...

Page 4: ...from this product Use appropriate shielding RISK GROUP 3 Caution Label IEC 62471 2 2009 Caution Hot Surface Notice UV radiation emitted from this product Hot Surface Located on 365 385 nm LED head as...

Page 5: ...5 00628R Hand held use of the LED heads is not recommended and may expose the user to dangerous optical radiation Additionally to prevent unintentional exposure use of the on off key switch on the LX5...

Page 6: ...0 00054R 6mm Replaceable Lens 810 00060R 8mm Replaceable Lens 810 00061R 10mm Replaceable Lens 810 00066R 12mm Replaceable Lens 810 00078R 5mm Cylindrical Lens 810 00083R 90deg Adapter 6mm spot 810 00...

Page 7: ...er Guide 035 00628R of for Installation procedures LED Head Cap Assembly Removal Procedures Clamp Heat Sink Installation Removal Procedures Lens Changing Procedures 4 Routine Care and Maintenance Caut...

Page 8: ...portional to the setup accuracy during the calibration process 2 Typical Optical Power shown A difference of up to 20 between different LED heads may be possible Wavelength 365 5nm V3 LED Head 2 Power...

Page 9: ...e setup accuracy during the calibration process 2 Typical Optical Power shown A difference of up to 20 between different LED heads may be possible Wavelength 385 5nm V3 LED Head 2 Power typical 1100 m...

Page 10: ...e setup accuracy during the calibration process 2 Typical Optical Power shown A difference of up to 20 between different LED heads may be possible Wavelength 395 5nm V3 LED Head 2 Power typical 1100 m...

Page 11: ...accuracy during the calibration process 2 Typical Optical Power shown A difference of up to 20 between different LED heads may be possible Wavelength 405 5nm V3 LED Head 2 Power typical 1000 mW 1 Peak...

Page 12: ...ve Council Directive 2014 30 EU EMC Directive Council Directive 2012 19 EU WEEE Directive Council Directive 2011 65 EU as amended by EU 2015 863 RoHS 5 4 China RoHS The symbol above indicates that thi...

Page 13: ...nd to diminish the pressure on the natural resources we encourage you to use the appropriate take back systems Those systems will reuse or recycle most of the materials of your end life equipment in a...

Page 14: ...its original shipping case or as appropriate to prevent damage during transport In the case of damage caused by wear and tear careless handling neglect by the use of force or in the case of interventi...

Page 15: ...2055 https www excelitas com product category uv curing systems https www excelitas com ox_service_request_form https www excelitas com omnicure x cite inquiries Technical Assistance techsupport excel...

Reviews: