Excelair EPA 16 Instruction Manual Download Page 10

OPERATION

Turning ON/OFF

Adjust the louvers to desired angle and position.

Press ON/OFF button, the unit will start to work. If the ambient temperature is 

z

higher than 23

o

C, the unit will work in cool mode.

z

higher than 20

o

C but below or equal to  23

o

C, the unit will work in ventilation model.

z

below 20

o

C, the unit will work in heat function (This is for cooling & heating models 

only.),

Indicators of the functions in progress come on at the same time. *NOTE! The display 

window shows the ambient room temperature from 0

o

C to 50

o

C

To turn the unit off, press ON/OFF button again, then close the air louvers.

Setting mode/function

Press MODE button to select required working mode: automatic, cooling, fan or h

eat

(Heat is 

only available for heating & cooling models.)

Indicator of the selected mode comes on.

Setting temperature

1.

Press 'Temperature up' or 'Temperature down' button to regulate the temperature you 

desired.

2.

The display window will show the temperature you set as you press 'Temperature up' or 

'Temperature down' button. Otherwise, it will always show the ambient temperature.

3.

The pre-setting temperature of this machine is:  24

o

C for cooling, 20

o

C for heating.

Setting ventilation speed

1.

Press SPEED button to choose the ventilation speed you need, high, medium or low. 
The sign of high, low  or medium ventilation will light on at the same time.

2.

If the unit is in AUTO mode, it will choose the ventilation speed automatically according 
to the ambient temperature.

Setting timer

1.

Press TIMER button to set the operating hours you desired (1 to 24 hours, the sign of 

timer will light on). The windowwill show the hour(s) you set as you press TIMER button. 

If the timer button is not pressed, the unit will work continuously.

2.

By pressing the timer but without turning on the other functions, you can PRE-SET the 

time for the machine to work. For example, if you press the timer to '2', the unit will work 

automatically after 2 hours.

9

Summary of Contents for EPA 16

Page 1: ...Distributed in Australia by Honeyair Australia Pty Ltd 78 Mallard Way Cannington WA 6107 P 1300 710 860 F 1300 710 890 E info gbi com au Instruction Manual Model EPA 16 Portable Airconditioner...

Page 2: ...l Fan speed 3 Timer 1 24 hours Working temperature Cooling 18 32 o C Heating 7 25o C Exhaust pipe 142x1500mm Net Weight 35kgs Dimension 422x443x825 mm WxDxH REMARK 1 Measuring condition for above is a...

Page 3: ...ENTAL CAPABILITIES OR LACK OF EXPERIENCE AND KNOWLEDGE UNLESS THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR SAFETY CHILDREN SHOULD B...

Page 4: ...ds closed during the sunniest part of the day x Keep filters clean x Once room has reached the desired conditions reduce temperature and ventilation setting FIG 4 PARTS Front Back 1 Control Panel 2 Ai...

Page 5: ...rol 17 Active carbon filter 18 Tube for continuous drainage FIG 7 INSTALLATION OF THE EXHAUST PIPE The unit is a portable air conditioner that may be moved from room to room 1 Using the PVC strip x Of...

Page 6: ...a 151mm diameter hole in the wall or window x Feed exhaust hose through the window or wall and attach the threaded adaptor from the outside as shown x When not in use plug the hole with the cover pro...

Page 7: ...up causing the unit to overheat and shut down Fig 8 9 show correct position x The hose may be extended from 300mm to 1500mm but for maximum efficiency use the shortest length possible WARNING The leng...

Page 8: ......

Page 9: ...on 8 TIMER button 9 VENTILATION fan speed button Signs in the LCD FIG 16 10 Sign for Timer showing the working hour you set 11 Room temperature display 12 Sign for Sleep function 13 Sign for Centigrad...

Page 10: ...button to regulate the temperature you desired 2 The display window will show the temperature you set as you press Temperature up or Temperature down button Otherwise it will always show the ambient...

Page 11: ......

Page 12: ......

Page 13: ...e 3 Remove the drain knob rubber plug from the drain hole and allow the water to drain out 4 When the container is almost full replace the rubber plug in the drain hole and empty the water tray 5 Repe...

Page 14: ...t with another tube OD 18mm FIG 22 Special caution for heating function While using the heating function please note 1 Install the exhaust pipe well in order to exhaust the cool air to outdoor Please...

Page 15: ...m cleaner or tap the filter lightly to remove loose dust and dirt from the filters and then rinse thoroughly under running water no hotter than 40o C Dry thoroughly before replacing Notice Never opera...

Page 16: ...y people in the room y Is there something in the room producing lots of heat The machine seems to do nothing y Is the filter dusty contaminated y Is the air intake or output blocked up y Is the room t...

Page 17: ...e If unit is deemed to be faulty it will be replaced during the 12 month warranty period Distributed in Australia by Honeyair Australia Pty Ltd ABN 86 008 764 341 78 Mallard Way Cannington WA 6107 Pho...