Excel Dryer XLERATORsync Installation And Owner'S Manual Download Page 5

E X C E L   D R Y E R ,   I N C           1 . 4 1 3 . 5 2 5 . 4 5 3 1           1 . 8 0 0 . 2 5 5 . 9 2 3 5   ( U S / C N )           E X C E L D R Y E R . C O M

A D M I N @ E X C E L D R Y E R . C O M           3 5 7   C H E S T N U T   S T R E E T,   E A S T   L O N G M E A D O W,   M A   0 1 0 2 8

5 / 2 0 2 0

5

R E A D  A N D   S AV E   T H E S E   I N S T R U C T I O N S

Dryer does not turn on

1.    Check LED indicator light on the front of the sink box under the sink

  

Light is out

 – Check to make sure the unit is plugged in and that the outlet  

 

 

has power. 

 

 

If power is confirmed but no light visible, send dryer back for service.

  

Light is flashing

 – Check Code Chart for remedy

  

Light is solid 

– Place hands under sensor at spout (white light in spout should  

 

 

go on) at the same time check red LED service indicator light under sink - if still  

 

 

on, check sensor cable connection at dryer. Check sensor connection at spout.

 

 

If all OK then replace sensor.

 

 

NOTE: Normal operation of spout LED light when first powered up is to

 

 

flash RED / GREEN / BLUE.  After lights go off the light will go on white when  

 

 

hands are placed under sensor.

 

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, 

OBSERVE THE FOLLOWING:

A. Use this unit only in the manner intended by the manufacturer.
B.  Before servicing or cleaning unit, unplug power cord from receptacle. 

CLEANING / MAINTENANCE

OUTSIDE

  

 Gently wash spout using a soft cloth or sponge and a mild soap or detergent with lukewarm water to loosen dirt and grime. Do not 

use an abrasive cleaner.  

INSIDE

 

Excel recommends inspecting for lint on the Pre-Filters and HEPA filter. 

 

 

DO NOT CLEAN THE HEPA FILTER OR ALLOW IT TO COME INTO CONTACT WITH WATER. 

TROUBLESHOOTING

R E A D  A N D   S AV E   T H E S E   I N S T R U C T I O N S

7-YEAR LIMITED WARRANTY

 (U.S. Only)

1.   This product is warranted to be free of manufacturing defects for seven (7) years (one [1] year on HEPA Filter & Pre-Filter) from the date of shipment 

from the Manufacturer’s factory at 357 Chestnut St., East Longmeadow, Massachusetts 01028. This warranty explicitly excludes normal wear and 

tear on the Filter or Pre-Filter, as well as faulty installation, accident, misuse, or vandalism. In the event of a breach of the warranty described above, 

the Owner shall have either one of the following remedies:

 

a. 

 The Owner shall return the defective product to the Manufacturer, postage prepaid, and the Manufacturer shall repair said product within a 

reasonable time and free of charge, provided that said product is returned within the stated period above from  the date of original shipment 

from the Manufacturer’s factory in East Longmeadow, Massachusetts; and, provided further that said defect is not due to faulty installation, 

accident, misuse, or vandalism; or

 

b. 

 The Owner may notify the Manufacturer by telephone or in writing of the defect and, within a reasonable time, the Manufacturer shall send a 

suitable replacement  part to remedy said defect, and Owner shall be charged for said part at the current price level. The Owner may return 

the defective part to the Manufacturer, postage prepaid, along with the serial number of the defective product and the Manufacturer will then 

issue to the Owner a full credit for the repair part, including outgoing postage (within the Continental U.S. only).  Said remedy is available only 

within the stated period stated above from the date of original shipment of the product from the Manufacturer’s factory in East Longmeadow, 

Massachusetts, and provided further that said defect is not due to faulty installation, accident, misuse, or vandalism.

2.   Any implied warranties of merchantability or fitness for a particular purpose are hereby limited to the duration of the express written warranty 

contained in paragraph one (1); namely, seven (7) years (one [1] year on HEPA Filter & Pre-Filter) from the date of shipment from the Manufacturer’s 

factory in East Longmeadow, Massachusetts.

3.   There are no other warranties and remedies except as contained herein. This warranty shall inure to the benefit of the Owners, Successors 

 

and Assigns.

Dryer blows only cold air

1.    Check heat setting on Dryer Box.
2.  Run dryer for 10 seconds to warm up. If still cold, send dryer back for service.

ADJUSTING THE HEAT OUTPUT, MOTOR SPEED

The dryer is shipped with maximum heat and maximum motor speed.  

To adjust, turn the corresponding knob COUNTER-CLOCKWISE to reduce.

H = HEAT     M = MOTOR

Dryer has loss of air volume

1.   Check motor speed setting on control.

2.  Check hose connection under sink.

3.  Check HEPA Pre-Filter for lint buildup. Clean by removing Pre-Filter and  
 

rinse in warm water then dry before reinstalling.

Reviews: