2.
Press and hold the Water Softener UP & DN buttons
together for three seconds until the motor drive starts. Wait
until the motor stops in the backwash position displaying C1.
3.
Open the inlet handle of the bypass valve very slowly
allowing water to fill the Water Softener slowly to expel air
out the drain line. If water flows too rapidly, there will be a
loss of media out of the drain.
4.
When the Water Softener is flowing steadily to drain without
the presence of air, press the DN button to advance the
Water Softener control valve to the brine draw position, C2.
5.
Fully open the inlet of the Water Softener bypass valve
(bypass is no in the diagnostic position). Check to verify that
water is being drawn from the brine tank. There should be a
slow flow to the drain. Allow three minutes for the media bed
to settle.
6.
Press the Water Softener DN button to advance the Water
Softener control valve to where the display C3 which is a
second backwash with water running steadily to drain.
7.
Press the Water Softener DN button to advance to C4 which
is the fast rinse cycle that will settle the resin bed back to the
service position after backwashing.
8. Press the Water Softener DN button to advance to C5 which
is the refill stage where you should have water refilling back
into the salt storage brine tank.
8.
Press the Water Softener DN button to advance to C5 the
control valve back will go through a quick wash.
9. Press the Water Softener DN button to advance to C0 which
will send the control valve back into the service position
properly displaying the current time of day.