12
SOFTENER INSTALLATION AND USER GUIDE
BARRIE • ONTARIO • CANADA 705.733.8900 WWW.EXCALIBURWATER.COM
3)
MODEL VARIABLE COMPONENTS AND SPECIFICATIONS
3.1)
Flow Controls and Injectors
Model Number
Mineral Tank
Brine Tank
Injector
Drain Flow Control
Dia X Height (Inch)
(Inch)
Color
Order #
Flow GPM
Order #
EWS SP27BFJCT
9x48
18x33 (Dia x
Height)
Red
CLK V30101D
2.2
CLK V3162022
EWS SP34BFJCT
9x48
Red
CLK V30101D
2.2
CLK V3162022
EWS SP46BFJCT
10x54
White CLK V30101E
2.7
CLK V3162027
EWS SP56BFJCT
10x54
White CLK V30101E
2.7
CLK V3162027
EWS SP66BFJCT
12x52
Blue
CLK V30101F
3.2
CLK V3162032
3.2)
Specifications
*Excalibur Softeners are factory programmed to 10lbs/ft
3
default settings
Model Number
Mineral
Tank
Resin
Quantity
Grains Capacity
Lbs Salt Setting
Flow (GPM)
Shipping
Weight
Dia X
Height
ft
3
6lbs Salt/ft
3
10lbs Salt/ft
3
15lbs Salt/ft
3
Continuous Peak
LBS
EWS SP27BFJCT 9X48
0.90
18,000 5.5 24,000 9.0 27,000 14.0
4.5
7.2
77
EWS SP34BFJCT 9X48
1.17
23,000 7.0 31,000 12.0 35,000 18.0
5.7
9.4
93
EWS SP46BFJCT 10X54 1.53
31,000 9.0 41,000 15.0 46,000 23.0
7.7
12.2
116
EWS SP56BFJCT 10X54 1.87
37,000 11.0 50,000 19.0 56,000 28.0
9.4
15.0
134
EWS SP66BFJCT 12X52 2.20
44,000 13.0 59,000 22.0 66,000 33.0
11.0
17.6
182
Step 8S –
Select “dn” for downflow brine cycle using
▲
or
▼
. Press
NEXT to go to Step 9S. Press REGEN to return to previous step.
Step 9S –
Set “NORMAL” for the regeneration time. Press NEXT to
exit Softener System Setup or Press REGEN to return to previous
step.
EXIT SOFTENER SYSTEM SETUP