Exalt Installation and Management Guide
EX-i Series FDD Digital Microwave Radios
66
202675-005
2011-08-30
Alarms Page
This page provides an easy-to-read summary of the alarm status of both local and remote radios. The
colors on this page reflect the color of the alarms displayed on the radio front panel. However,
additional detail displays on this page to aid in quick assessment of issues and status.
Figure 46 Alarms page
Table 5 lists alarm status conditions that appear on this page.
Table 5 Alarm status indicators
Label
Status
Link System
Indicates RF link status:
• Green Solid = Error-free connection (BER<10e-6)
• Yellow Solid = Errored connection (10e-3>BER >10e-6)
• Red Solid = No link (BER>10e-3)
RX Alarm
When Rx RSL Differential is enabled, provides alarms for Space Diversity configurations.
• Green Solid = The Rx values of the two receivers are within 5dB of the programmed
differential value.
• Yellow Solid = The Rx values of the two receivers are further apart than 5dB of the
programmed differential value.