EX-r Series GigE Digital Microwave Radios
7
201872-003
2015-10-23
The two radio terminals are identical hardware, except for the TDD setting in software. When the
radios are in their default state, both radios are configured as Radio B.
One end of the link must be
configured as Radio A before the two ends of the radio system can communicate.
It can be considered that Radio A is the primary radio in the link. Radio A provides the master clock
and control to Radio B. For most applications, it is not important how the radio link is oriented, only
that one end is configured for Radio A and the other for Radio B. For some applications (such as,
multi-radio hub sites or repeaters), the orientation of the radio systems may be more critical. See
Orientation and Synchronization
for details.
There are two ways to configure the radios for Radio A/B determination:
•
Use the Exalt browser-based graphical user interface (GUI) – preferred.
•
Connect to the radio using Telnet.
Exalt recommends using the Exalt GUI for radio configuration. This interface requires a computer
with an Ethernet port and web browser software, such as Microsoft Internet Explorer 5.0 or above. See
for details on how to connect to and use the browser-based GUI
interface.
Shipping Box Contents
Unless purchased as a spare terminal, the radios are shipped as a complete
hop
(that is, a radio link pair
consisting of two terminals). An outer box has labeling that indicates the contents of the box, with the
part number and serial number details for both radio terminals.
Inside the outer box are two identical boxes, each of these boxes is also marked with the part number
and serial number of the individual terminal contained inside the box. The terminal box contains the
following items:
•
Radio terminal (configured as Radio B)
•
AC adapter
•
Power injector
•
Mounting kit (for pole or wall mounting)
•
Accessory kit
–
Grounding screw/washers
–
Weather-sealing tape (required for RF connectors on the EX-5r-c GigE)
–
RF connector cover (for the EX-4.5r-c GigE or EX-5r-c GigE covering the unused RF
connector, where applicable)
–
RSL adapter cable
•
Registration card
•
Quick-start guide
Inspect the outer packaging and the contents of the boxes upon receipt. If you suspect any shipping
damage or issues with the contents, contact Exalt Customer Care.
Note:
Register your system as soon as possible.
A 2-year Warranty period applies to
products registered within 90 days of purchase. The Warranty period is reduced to 1-year for
unregistered products and products registered after the first 90 days.