EXAIR EFC Installation And Maintenance Download Page 4

LIT 9003 

©2012 EXAIR Corporation 

TROUBLESHOOTING 

If the EFC provides inconsistent timing or sensing, it might be located in an area with excess electronic noise. Under these 
conditions, separate the timer control unit, wiring, and sensor cable (which generates the input signals) as far as possible from the 
noise source(s). To further prevent electronic interference, shield the sensor cable. 
 
If there is power to the EFC but the power switch does not light, it is possible that the internal fuse has blown. To replace the fuse, 
first, unplug the unit (remove power). With the cover removed, a modular plastic fuse housing is visible. The door of the housing 
opens to the side. The fuse holder is rated 5 amps. Replacement fuse is BUSS AGC 5A rated 250V. 
 
The relay has a life expectancy 100,000 operations minimum. (This is based on 5A at 250VAC, with a resistive load at 360 
operations/h.) 

 

CLEANING, MAINTENANCE AND STORAGE 

Periodically inspect the EFC unit, wiring and parts for damage. If any damage is observed, do not use the equipment and contact 
EXAIR for replacement parts as applicable. 
 
If it becomes necessary to replace the fuse, use a ¼” x 1-1/4” (6.4mm x 32mm) 5A, 250V Fast Acting fuse. 
 
Organic solvents such as paint thinner, as well as very acidic or basic solutions can damage the outer casing of the timer. Clean 
with a soft cloth or mild detergent. 
 
When storing the EFC, make sure that the ambient temperature and humidity are within the rated values. If the EFC has been 
stored at an ambient temperature of -10°C or below, the unit must sit at room temperature for at least three hours before using it 
for the EFC to function properly. 

 

EQUIPMENT ENVIRONMENTAL RATINGS 

Installation Category II (Transient Over-voltage) 
Pollution Degree 2 (Temporary conductivity caused by condensation) 
Altitude Limit: 6,562 ft (2,000 m) 
Humidity: 80% RH non-condensing 
EFC is intended for indoor and outdoor use 

 

WARRANTY 

There is a one year warranty against defects in workmanship and materials. Defective products must be returned freight prepaid 
for repair or replacement at EXAIR’s option. This warranty applies under the conditions of normal use, but does not apply to 
defects that result from intentional damage, negligence or unreasonable use or exposure. The EFC has no serviceable parts 
internally. Warranty is void if there is evidence of tampering.  

 

 

If you have any questions or problems, please contact an EXAIR Application Engineer at: 
 

Toll Free: 1-800-903-9247 (U.S. and Canada)             
Telephone: (513) 671-3322 outside of U.S. and Canada 
Toll Free Fax: 1-866-329-3924 (U.S. and Canada)      
FAX: (513) 671-3363 outside of U.S. and Canada 
E-mail: [email protected]                                          
Website: www.exair.com 