background image

19

eXact

®

 Eco-Check Reagent Reorder Information

N/A

9 - 210 ppm

0 - 2.4 ppm

3 - 270 ppm

0 - 5 ppm
0 - 5 ppm

0 - 11 ppm

60 - 600 ppm

0.12 - 30 ppm

0 - 1.8 ppm

5.1 - 9.2 pH

5 - 9.2 pH

0 - 4 ppm

PARAMETER

No.

AES Item #

# OF TESTS DETECTION RANGE

CHEMISTRY

H;DFWŠ6WULS0LFURP/5HDJHQW6SHFLÀFDWLRQV)RUXVHZLWKH;DFWŠ(FR&KHFN

Dilution Kit
Alkalinity, Total (as CaCO

3

)

Ammonia (as NH

3

)

Ammonia Reagent
Chloride III (as NaCl)
Chlorine, Free
Chlorine, Combined*
Copper (as Cu

+2

)

Hardness, Total High (as CaCO

3

)

Nitrate (as NO

3

)

Nitrite (as NO

2

)

BT-pH (Fresh Water)
BT-pH (Salt Water)
Phosphate (as PO

4

)

1
2

3
4
5
6
7
8
9

10

11

12

487200
486641

486654-A
486654-B

486757
486637
486638
486632
486656
486655
486623
486657
486657
486814

N/A
100

25
25
25

100
100

50
50
50
50
50
50
50

N/A

Alizarin Red S + Citrate

Salicylate Method

Silver

DPD

Kl

Biquinoline

Phtalein Purple

Zinc + Chromotropic Acid + SA

Chromotropic Acid + SA

Bromothymol Blue
Bromothymol Blue

Molybdate Antimony

NOTE: Because most of our products are test strips or use reagents that have little or no hazard in the quantity sold, MSDS sheets are not 
supplied with the test.

To ensure optimal performance, store your eXact

®

 kit in a cool, dry place away from excess heat (below 

90°F / 32°C), moisture, and oxidizers such as Chlorine and Bromine.

$ERXW7KH$FFXUDF\&DOLEUDWLRQ2I7KHH;DFW

®

(FR&KHFN6\VWHP

$OOWHVWVKDYHEHHQFDOLEUDWHGXVLQJFHUWL¿HGUHIHUHQFHVWDQGDUGVDQGVWDQGDUGDQDO\WLFDO
VSHFWURSKRWRPHWULFPHWKRGV7KHDOJRULWKPVLQWKHVRIWZDUHUHÀHFWWKHEHVWFRUUHODWLRQRIWKHH;DFW

®

 

Eco-Check Systems against the AWWA, US EPA , DIN, and ISO reference test methods for chlorine. 

6WXGLHVVKRZWKDWWKHH;DFW

®

 Eco-Check System repeatedly agrees with an EPA Compliant reference 

method greater than 99% (R

2

 SSPVHHSDJH7KHH;DFW

®

 Eco-Check Advanced 

3KRWRPHWULF6\VWHPKDVEHHQIDFWRU\FDOLEUDWHGIRU\RXUFRQYHQLHQFH<RXFDQH[SHFWWKH¿[HG

calibrations in the meter to be valid for the life of the meter because of the quality, Long-Life LED, the 
photo cell, and the software as written into the meter. NOTE: Test algorithms in this meter give accurate 
results in fresh and salt water (except Nitrate)

&RPSOLDQFH9HULÀFDWLRQIRU)UHHDQG7RWDO&KORULQH7HVWLQJ

This DPD test system is accepted by most state health departments because this test is USEPA (DIN 
Standard 38 408 G4, ISO 7393/2) accepted for testing requirements for Free and Total Chlorine. The 

H;DFW

®

 Eco-Check meter uses a wavelength of 525nm; and the compliance requirement is that the 

FRORULPHWHUZDYHOHQJWKLVEHWZHHQDQGQP7KHH;DFW

®

 Strip Micro CL (DPD-1) uses the same 

UHDJHQWVDQGSURSRUWLRQVDQGWKHUHVXOWLQJVRLVPDLQWDLQHGEHWZHHQDQGDVVSHFL¿HG

by AWWA (American Water Works Association) method 4500-Cl G. It should be understood that the 
USEPA does not "approve" commercial DPD delivery systems such as reagent powder pillows, tablets, 

GLVSHQVHUVRUH;DFW

®

6WULS0LFUR'3'GHOLYHU\GHYLFHV7KHH;DFW

®

 Strip Micro CL (DPD-1) for Free 

&KORULQHDQGWKHH;DFW

®

6WULS0LFUR&/'3'RUWKHH;DFW

®

 Strip Micro CL (DPD-4) for Total Chlorine 

PHHW\RXUUHSRUWDEOHWHVWLQJUHTXLUHPHQWVEHFDXVHWKHH;DFW

®

 Strip Micro CL delivers the same 

chemicals in identical proportions (see table below); therefore, the system is compliant. Likewise, 
AWWA proportions are followed as required for Total Chlorine measurements using Potassium Iodide.

AWWA

4500-C

O*

eXact

®

DPD-1

Anhydrous DPD sulfate
Anhydrous Na

2

HPO

4

Anhydrous KH

2

PO

4

Na

2

EDTA 

1.5%

33.4%
64.0%

1.1%

1.5%

33.4%
64.0%

1.1%

Component

(

)

ree Ch

O

orine)

&RPELQHG&KORULQH7HVWUHTXLUHV)UHH&KORULQHWREHUXQ¿UVW

Summary of Contents for Eco-Check

Page 1: ...dard Kit The eXact Eco Check Dual Wavelength Photometer System is designed for use with the eXact Strip Micro reagent delivery system eXact Eco Check is Manufactured and tested in an ISO 9001 Facility Dual Wavelength Advanced Photometer System U S Patent No 7 333 194 U S Patent No 7 491 546 South African Patent No 2007 0628 EU Patent 1 725 864 and International Patent Appln No PCT US2005 033985 US...

Page 2: ... 13 oz Operating Temperature Range 0 50 C 32 122 F Power Supply 4 AAA alkaline batteries Not Included Battery Life 2000 tests with alkaline batteries Electromagnetic Compliance Emitted Interference EN 61326 EMC Immunity to Interference EN 61326 Waterproof Rating Exceeds IP67 Weight Instrument 181 g 6 4 oz Dimensions Instrument 5 W x 3 5 D x 16 5 H cm 2 x 1 4 x 6 5 in 1 2SWLPDO ZDWHU WHPSHUDWXUH LV...

Page 3: ...Continue holding down the MENU key to scroll the stored results for that test starting with the most recent result The meter will display from memory the last 20 readings in sequence beginning with 20 which is the latest result followed by 19 which is the 2nd ODWHVW UHVXOW HWF DQG QDOO 01 which is the oldest result retained Only the last 20 readings are stored in each menu This meter is able to st...

Page 4: ...s 10 allow countdown to continue RECORD RESULT DISPLAYED The cursor will move across the display while the meter prepares to measure the sample Record result displayed this result is automatically stored in AL1 Menu After testing is completed rinse cell immediately ZERO METER Press the ZERO ON button The cursor will move across the display followed by 0 00 PPM The sample is ready for testing RINSE...

Page 5: ...EAD This starts the 20 SECOND countdown timer During this time move the strip in a gentle back and forth motion approx 2 strokes sec Remove and discard the strip after 1 on the display disappears The meter will automatically start to count up for 360 seconds 6 minutes DIP STRIP AND PRESS READ RECORD RESULT DISPLAYED After the 360 seconds the cursor will automatically move across the display while ...

Page 6: ...er 1 on the display disappears The meter will automatically start to count up for 600 seconds 10 minutes DIP STRIP AND PRESS READ RECORD RESULT DISPLAYED After the 600 seconds the cursor will automatically move across the display while the meter prepares to measure the sample Record result displayed this result is automatically stored in NO3 Menu After testing rinse cell and clean with brush Press...

Page 7: ...s READ This starts the 20 SECOND countdown timer During this time move the strip in a gentle back and forth motion approx 2 strokes sec Remove and discard the strip after 1 on the display disappears The meter will automatically start to count up for 500 seconds DIP STRIP AND PRESS READ RECORD RESULT DISPLAYED After the 500 seconds the cursor will move across the display while the meter prepares to...

Page 8: ...automatically stored in TH5 Menu After testing is completed rinse cell immediately and use brush to remove any residual from previous test 7 ZERO METER Press the ZERO ON button The cursor will move across the display followed by 0 00 PPM The sample is ready for testing 5 SELECT TEST TH5 Press and re press the MENU button until the display shows the parameter TH5 3 DIP STRIP AND PRESS READ Dip the ...

Page 9: ...potential for cross contamination from a previous test LQDOO OO FHOO WR FDSDFLW ZLWK WKH ZDWHU VDPSOH SELECT TEST CL6 Press and re press the MENU button until the display shows the parameter CL6 CL6 is also used for testing Free Chlorine DPD 1 Ozone DPD 4 Permanganate DPD 1 and Total Chlorine DPD 3 Contact ITS for specs and details if you are planning on using CL6 for Permanganate or Ozone measure...

Page 10: ... pH the sample is ready for testing Tilt the meter to discard about 0 2mL of water sample in order to leave room for liquid reagent RINSE AND FILL CELL WITH SAMPLE Rinse the CELL at least 3 times with the water sample you will be testing rinsing minimizes the potential for cross contamination from a previous WHVW LQDOO OO FHOO WR FDSDFLW ZLWK WKH ZDWHU sample SELECT TEST bt7 Press and re press the...

Page 11: ... move across the display while the meter prepares to measure the sample Record result displayed this result is automatically stored in PO8 Menu After testing rinse cell immediately ZERO METER Press the ZERO ON button When the display shows 0 00 PPM the sample is ready for testing RINSE AND FILL CELL WITH SAMPLE Note Clean the CELL with Distilled Vinegar 5 0 1 N HCl or Muriatic Acid Rinse the CELL ...

Page 12: ... measure the sample Press READ again If this reading matches the previous result then record this as the Copper value If not matching some water samples may require a 2 ZERO METER Press the ZERO ON button When the display shows 0 00 PPM the sample is ready for testing RINSE AND FILL CELL WITH SAMPLE Rinse the CELL at least 3 times with the water sample you will be testing rinsing minimizes the pot...

Page 13: ... will move across the display while the meter prepares to measure the sample Record result displayed this result is automatically stored in CH0 Menu After testing rinse cell immediately and clean with brush ZERO METER Press the ZERO ON button When the display shows 0 PPM the sample is ready for testing RINSE AND FILL CELL WITH SAMPLE Rinse the CELL at least 3 times with the water sample you will b...

Page 14: ...pH the sample is ready for testing Tilt the meter to discard about 0 2mL of water sample in order to leave room for liquid reagent RINSE AND FILL CELL WITH SAMPLE Rinse the CELL at least 3 times with the water sample you will be testing rinsing minimizes the potential for cross contamination from a previous WHVW LQDOO OO FHOO WR FDSDFLW ZLWK WKH ZDWHU sample SELECT TEST P11 Press and re press the ...

Page 15: ...ntration DO NOT discard the sample from the Free Chlorine test if you are planning to run eXact Strip Micro DPD 3 Combined Chlorine Procedure Move directly to steps 7 9 on page 16 Otherwise rinse the cell immediately NOTE When testing outdoors sunlight for best accuracy use the Mixing Cap Cell Cover when Zeroing and Reading the sample 6 Dip the eXact Strip Micro CL DPD 1 Part No 486637 into the CE...

Page 16: ...s and then make your measurement NOTE From testing in our lab water samples above 70 F 20 C generally reach a stabilized reading quicker then 2 minutes eXact Strip Micro CL DPD 1 DPD 3 DPD 4 Interferences Part Nos 486637 486638 486670 Interfering Substance Acidity Alkalinity Bromine Bromamines Br2 Chlorine Dioxide ClO2 Copper Cu 2 Iodine I2 Manganese oxidized Mn 4 Mn 7 or Chromium oxidized Cr 6 Mo...

Page 17: ...ldren and pets Each bottle of eXact Strip Micro contains the quantity of strips notated on the bottle RX PD QG RQH RU WZR VWULSV WKDW DUH QRWLFHDEO VPDOOHU RU ODUJHU LQ ZLGWK WKDQ WKH normal strips in the bottle These should be discarded Using these strips may give unreliable results The eXact Eco Check meter is not compatible for use with DPD 1 DPD 3 and DPD 4 powder pillows tablets and liquids a...

Page 18: ...l regularly is especially recommended after you run a WHVW WKDW LV XVLQJ WXUELGLW RU LQF GXVW FKHPLVWU IRU DQDO VLV KORULGH DQG 1LWUDWH eXact Photometer 2 Year Limited Warranty Registration of your eXact photometer must be received within 30 days from date of purchase to activate the warranty The eXact photometer is warranted to be free from defects in materials and ZRUNPDQVKLS IRU D SHULRG RI WZR...

Page 19: ...rees with an EPA Compliant reference method greater than 99 R2 SSP VHH SDJH 7KH H DFW Eco Check Advanced 3KRWRPHWULF 6 VWHP KDV EHHQ IDFWRU FDOLEUDWHG IRU RXU FRQYHQLHQFH RX FDQ H SHFW WKH HG calibrations in the meter to be valid for the life of the meter because of the quality Long Life LED the photo cell and the software as written into the meter NOTE Test algorithms in this meter give accurate ...

Page 20: ...act Reagent Ammonia 486654 B 25 eXact Strip Micro Nitrate 486655 25 eXact Strip Micro Nitrite 486623 25 eXact Strip Micro Phosphate 486814 25 eXact Strip Micro Chloride 486757 Mini Dilution Kit II 487202 1 Mixing Cap 1 Cell Cleaning Brush Instruction Booklet Plastic Carrying Case For US Inquiries and Re Orders Industrial Test Systems Inc 1875 Langston Street Rock Hill SC 29730 USA Phone 1 800 861 ...

Reviews: