A Series 4U Hybrid NVR Series Quick Start Guide
Camera connections
To connect cameras to the system, complete the following steps:
1.
Connect the analog cameras, PTZ serial cables, or alarm I/O. For more information, see Connections.
Note: Connections vary by model.
2.
Using the camera manufacturer’s software, configure the IP address for all the cameras, and record this information for future
reference.
Note: Do not change the username and passwords until after you establish connectivity with the exacqVision server.
For additional information, see the camera manufacturer’s website or the
exacqVision IP Camera Quick Start Guide at
http://www.exacq.com/downloads/ev-ip-quickstart-0311.pdf
. You may also find the Quick Start Guide in the Quickstarts
directory on the CD that Exacq dispatch with your system.
3.
To determine the compatibility of a particular camera model and firmware combination with exacqVision servers, use the
following link:
http://www.exacq.com/support/ipcams.php
4.
Test the connectivity between the camera and the server by completing the following steps:
a.
Log off of the operating system's user account and log on to the administrator account, using the following credentials.
Username: admin
Password: admin256
b.
Type the camera’s IP address into the address bar on your internet browser.
c.
Press Enter. If the browser does not display an introductory or logon window, the camera is not establishing a connection
with the server. Check the
exacqVision User Manual, and
www.exacq.com/kb
for a solution if the problem persists.
Repeat steps one to four for all other camera connections.
Connections
For information on the A-Series server’s back panel for Hybrid system, see Figures 2and 3and Tables 1 and 2.
Figure 2. A-Series Hybrid System back panel
Note: Optional second network interface card not shown in Figure 3 (available on IP Only system)
Name
No. of
Ports
Description
A Power*
1-2
100-240VAC 50/60Hz. Optional redundant power supply not shown (Connect
redundant power supply to separate power circuits)
B PS/2 connectors
2
PS/2 keyboard and mouse
C USB 2.0
2
USB keyboard, mouse, memory device, or DVD burner
D Video out
3
DisplayPort (D1), HDMI (D2), DVI-I (D3)
You may use a maximum of two video outputs simultaneously
E USB 2.0/3.0
4
USB keyboard, mouse, memory device, or DVD burner; USB 2.0 (E1) and USB 3.0
(E2)
F Audio in/out
3
Line in (blue); line out (green); microphone (pink)
G 10/100/1000 Ethernet
2
Dual on-board NICs
H Auxiliary Connections*
For more information, see detail in Figure 3.
I
Video In
64
Variable by model:
•
16 inputs and 16 looping outputs
•
32 inputs and 32 looping outputs
•
48 inputs
•
64 inputs
J Video Out
2-4
Availability and number vary by model
Table 1. A-Series Hybrid System back panel
Note: *Activate the power button on the front of the system to provide power to the system.
Auxiliary Connections
Figure 3. A-Series Hybrid System auxiliary connections
Table 2. A-Series Hybrid System auxiliary connections
Audio Block Connections
1-16 Line level audio in 1-16
Relay Block Connections
G
Common for all inputs
NO
Normally open relay output #1 (24V/1A max)
C
Relay common
NC
Normally closed relay output #2 (24V/1A
max)
G
Common for all inputs
RS-485 Block Connections
Tx+
PTZ control
Tx-
PTZ control
Rx+
PTZ control
Rx-
PTZ control
Trigger Inputs/Alarm Outputs Blocks
1-16 Trigger inputs 1-16
G
Common for all inputs
1-16 Alarm outputs 1-16
www.exacq.com
2 of 2
February 20, 2018, RevA