A Series 4U Hybrid NVR Series Quick Start Guide 

Camera connections 

To connect cameras to the system, complete the following steps: 

1.

 

Connect the analog cameras, PTZ serial cables, or alarm I/O. For more information, see Connections.  

Note: Connections vary by model. 

2.

 

Using the camera manufacturer’s software, configure the IP address for all the cameras, and record this information for future 
reference.  

Note: Do not change the username and passwords until after you establish connectivity with the exacqVision server.  

For additional information, see the camera manufacturer’s website or the 

exacqVision IP Camera Quick Start Guide at 

http://www.exacq.com/downloads/ev-ip-quickstart-0311.pdf

. You may also find the Quick Start Guide in the Quickstarts 

directory on the CD that Exacq dispatch with your system. 

3.

 

To determine the compatibility of a particular camera model and firmware combination with exacqVision servers, use the 
following link: 

http://www.exacq.com/support/ipcams.php

 

4.

 

Test the connectivity between the camera and the server by completing the following steps: 

a.

 

Log off of the operating system's user account and log on to the administrator account, using the following credentials.  

Username: admin 

Password: admin256 

b.

 

Type the camera’s IP address into the address bar on your internet browser. 

c.

 

Press Enter. If the browser does not display an introductory or logon window, the camera is not establishing a connection 
with the server. Check the

 exacqVision User Manual, and 

www.exacq.com/kb

 for a solution if the problem persists.  

Repeat steps one to four for all other camera connections. 

Connections 

For information on the A-Series server’s back panel for Hybrid system, see Figures 2and 3and Tables 1 and 2. 

 

Figure 2. A-Series Hybrid System back panel 

Note: Optional second network interface card not shown in Figure 3 (available on IP Only system)

 

 

Name  

No. of 

Ports 

Description 

A  Power* 

1-2 

100-240VAC 50/60Hz. Optional redundant power supply not shown (Connect 

redundant power supply to separate power circuits) 

B  PS/2 connectors  

PS/2 keyboard and mouse 

C  USB 2.0  

USB keyboard, mouse, memory device, or DVD burner 

D  Video out  

DisplayPort (D1), HDMI (D2), DVI-I (D3) 

You may use a maximum of two video outputs simultaneously 

E  USB 2.0/3.0  

USB keyboard, mouse, memory device, or DVD burner; USB 2.0 (E1) and USB 3.0 

(E2) 

F  Audio in/out 

Line in (blue); line out (green); microphone (pink) 

G  10/100/1000 Ethernet  

Dual on-board NICs 

H  Auxiliary Connections* 

 

For more information, see detail in Figure 3. 

Video In 

64 

Variable by model: 

 

16 inputs and 16 looping outputs 

 

32 inputs and 32 looping outputs 

 

48 inputs 

 

64 inputs 

J  Video Out  

2-4 

Availability and number vary by model 

Table 1. A-Series Hybrid System back panel 

Note: *Activate the power button on the front of the system to provide power to the system. 

Auxiliary Connections 

 

Figure 3. A-Series Hybrid System auxiliary connections 

Table 2. A-Series Hybrid System auxiliary connections 

Audio Block Connections 

1-16  Line level audio in 1-16 

Relay Block Connections

 

Common for all inputs 

NO 

Normally open relay output #1 (24V/1A max) 

Relay common 

NC 

Normally closed relay output #2 (24V/1A 

max) 

Common for all inputs 

RS-485 Block Connections 

Tx+ 

PTZ control 

Tx- 

PTZ control 

Rx+ 

PTZ control 

Rx- 

PTZ control 

Trigger Inputs/Alarm Outputs Blocks

 

1-16  Trigger inputs 1-16 

Common for all inputs 

1-16  Alarm outputs 1-16 

www.exacq.com

 

2 of 2 

 February  20, 2018, RevA

 