MAINTENANCE

When performing 

maintenance, you 

may be exposed to hot surfaces, 

water pressure, or moving parts that 

can cause serious injury or death!
Before performing any maintenance 

or repair, disconnect spark plug 

wire, let engine cool and release 

all water pressure. The engine 

contains flammable fuel.  DO NOT 

smoke or work near open flames 

while performing maintenance.

To ensure efficient operation and 

longer life of your pressure washer, a 

routine maintenance schedule should 

be prepared and followed. If the 

pressure washer is used in unusual 

conditions, such as high-temperatures 

or dusty conditions, more frequent 

maintenance checks will be required.

ENGINE

Consult the Engine Owners 

Manual for the manufacturer's 

recommendations for any and all 

maintenance. Consult the Engine 

Owners Manual for the manufactur-

er's recommendations for any and 

all maintenance. 

NOTE:

 The frame is 

equipped with an oil drain hole to help 

make changing the engine oil easier.

3.  Pull trigger on gun handle 

to 

relieve any water pressure.

4.

  Disconnect the wand from the 

gun.

5.  Remove the nozzle from the 

end of the wand

 with the 2mm 

allen wrench provided as shown.

6.  Clean the nozzle

 using the 

nozzle cleaner provided or a 

straightened paper clip. Insert 

into the nozzle end and work 

back and forth until obstruction is 

removed.

7.  Direct water supply into nozzle 

end

 to backflush loosened 

particles for 30 seconds.

8.

  Reconnect spark plug wire

9.  Reassemble the nozzle to 

the wand.

 Tighten securely to 

prevent leaks.

10.  Reconnect wand to gun 

and 

turn on water supply.

11.  Start pressure washer 

and 

place wand into high pressure 

setting to test.

NOZZLE CLEANING

If the nozzle becomes clogged 

with foreign matter, such as dirt, 

excessive pressure may develop. If 

the nozzle becomes partially clogged 

or restricted, the pump pressure will 

pulsate. Clean the nozzle immediately 

using the nozzle kit supplied and the 

following instructions:

1.  Shut off the pressure washer

 

and turn off the water supply.

2.  Disconnect spark plug wire

 to 

insure the unit will not start while 

performing maintenance.

PUMP

The oil in the high pressure pump was 

designed to last the life of the pump. 

If there is a problem with the pump 

contact an Authorized Service Center.

Summary of Contents for VR2320

Page 1: ...s 2 5 Carton Contents 6 Assembly Instructions 6 Operating Instructions 7 11 Maintenance 12 13 Storage 13 Trouble Shooting Guide 14 15 Warranty 16 Espa ol 17 32 Fran ais 33 48 Record All Information an...

Page 2: ...other similar items then an approved spark arrester must be installed and is legally required in the state of California It is a violation of California statutes section 130050 and or sections 4442 an...

Page 3: ...a location occupied by humans or animals Some cleaning fluids contain substances which could cause injury to skin eyes or lungs Use only cleaning uids speci cally recom mended for high pressure washe...

Page 4: ...re washers Wear protective clothing to protect eyes and skin from contact with sprayed materials Use of acids toxic or corrosive chemicals poisons insecticides or any kind of ammable solvent with this...

Page 5: ...HOW TO PREVENT IT Unsafe operation of your pressure washer could lead to serious injury or death to you or others Do not use chlorine bleach or any other corrosive compound Become familiar with the o...

Page 6: ...nto frame depress the snap buttons and slide the handle assembly onto the frame until snap buttons snap into place Registration card Nozzle Cleaning Tool Multi Adjustable Spray Wand Loosen Remove Scre...

Page 7: ...ing Solvents instructions in this section Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments Save this manual for future reference E...

Page 8: ...er the pressure it can be accomplished by these methods 1 Back away from the surface to be cleaned The further away you are the less the pressure will be on the surface to be cleaned 2 Rotate the nozz...

Page 9: ...deadly gas DO NOT let hoses come in contact with very hot engine muf er during or immediately after use of your pressure washer Damage to hoses from contact with hot engine surfaces will NOT be cover...

Page 10: ...ump HOW TO APPLY CHEMICALS AND CLEANING SOLVENTS Applying chemicals or cleaning solvents is a low pressure operation NOTE Use only soaps and chemicals designed for pressure washer use Do not use bleac...

Page 11: ...any water pressure in hose or spray gun 5 See Storage section in this manual for proper storage procedures 8 Start engine See Engine Owners Manual for correct procedure NOTE When engine rope is pulled...

Page 12: ...water pressure 4 Disconnect the wand from the gun 5 Remove the nozzle from the end of the wand with the 2mm allen wrench provided as shown 6 Clean the nozzle using the nozzle cleaner provided or a st...

Page 13: ...hield washer uid may also be used PUMP The manufacturer recommends using a pump protector winterizer such as when storing the unit for more than 30 days and or when freezing temperatures are expected...

Page 14: ...tion Water filter screen clogged Remove and clean filter Air in hose Turn off the engine then the water source Disconnect the water source from the pump inlet and turn the water source on to remove al...

Page 15: ...p in chemical injector Have parts cleaned or replaced by AWSC Worn seal or packing Have replaced by AWSC Worn or obstructed valves Have replaced by AWSC Worn unloader piston Have replaced by AWSC Chec...

Page 16: ...arrangements If the purchaser does not receive satisfactory results from the Authorized Warranty Service Center the purchaser should contact DeVilbiss Air Power Company THIS WARRANTY DOES NOT COVER M...