background image

Page 1

eWON500™

The Transparent Gateway

ver 1.0

9/11/05

User Guide

eWON500™ is a Multiprotocol Transparent Gateway!

 

MODBUS TCP

MODBUS RTU

EtherNet/IP

DF1

FINS TCP

FINS Hostlink

XIP

UNITELWAY

ISO TCP

PPI/MPI

VCOM

Proprietary

Summary of Contents for eWON500

Page 1: ...N500 The Transparent Gateway ver 1 0 9 11 05 User Guide eWON500 is a Multiprotocol Transparent Gateway MODBUS TCP MODBUS RTU EtherNet IP DF1 FINS TCP FINS Hostlink XIP UNITELWAY ISO TCP PPI MPI VCOM P...

Page 2: ...econtrol tasks through Ethernet The goal of the current document is to teach you how to correctly configure the eWON500 as a Transparent Gateway to address a wide range of various Programmable Logic C...

Page 3: ...the PLC The eWON500 configurable serial port Depending on the serial link which is supported by the target PLC the eWON500 serial port dip switches left bottom side from the eWON500 when you face its...

Page 4: ...o Half Duplex Let Master response timeout Rx message timeout and Tx message timeout empty default values applied Let Force Unitelway V2 and Disable 0 254 translation unchecked Set the ADO field to its...

Page 5: ...cable between your eWON500 and the PLC IO server configuration Go to the MODBUS IO server page Configuration IO Server Config MODBUS Edit Set the Baud Rate Parity and Stop Bit s according to your devi...

Page 6: ...et the Baud Rate Parity Stop Bit s Frame Error Detection according to your device and HW Mode to Full Duplex Let Master response timeout Rx message timeout and Tx message timeout empty default value a...

Page 7: ...INS Edit Set the Server Port and FINS TCP server node according to your device let the Routing Entry fields empty Set the Baud Rate Parity Databits Stop Bit s HW Mode and Reply Timeout with the requir...

Page 8: ...c A Enabled check box Special case for the FINS IO server select Fins Serial as the Protocol Let the Poll Rate value set to default Update the IO server configuration Tag Setup Go to the Tag Setup pag...

Page 9: ...WON500 embeds a page from which you can directly check the value from the Tags which match an existing word on a device from the serial bus Reading a Tag value in the eWON The Tag s monitoring page di...

Page 10: ...led s panel A label just close to the panel illustrates the various configurable modes in the eWON500 see illustrated table below Just set up the correct configuration then power OFF power ON the eWO...

Page 11: ...le issue occurs Moreover information is added to an eWON500 log file when it detects a problem From the Main Menu eWON toolbar click on Diagnostic then on Status and click on the I O server counter yo...

Page 12: ...nformation by selecting the required Event Class and by choosing the Reporting Level Error Warning or Trace Just don t forget to click on Update to refresh the page when done However if the displayed...

Page 13: ...m cable can be delivered as accessory to connect Shneider PLCs it has a SUBD9 connector at the eWON side and a MiniDIN connector at the PLC side MiniDIN PIN Schneider Signal Name eWON Signal Name eWON...

Page 14: ...parent Gateway ver 1 0 9 11 05 Page 14 User Guide 1747 CP3 cable between eWON and SLC 500 pinout The connectors are SUBD9 female at both sides 9 pin eWON 1 2 Rx 3 Tx 4 5 COM 6 7 RTS 8 CTS Table 2 1747...

Page 15: ...sparent Gateway ver 1 0 9 11 05 User Guide XW2Z S002 cable between eWON and OMRON PLC Pinout 9pin 9pin Dsub Female Dsub Male 3 SD SD 2 2 RD RD 3 7 RS RS 4 8 CS CS 5 5 SG SG 9 eWON NS series PT Table 3...