TECHNICAL DATA
Type
TDM
Voltage
115 VAC
115 V +/-10%
230 VAC
230 V +/-10%
Power
115 VAC
20 VA
230 VAC
20 VA
Protection class
IP65
Cable dimensions
3 x 0,75 mm
2
Connector
DIN EN 175301-803 form A
Time ON
0,5 s - 10 s
Time OFF
0,5 min - 45 min
Frequency
50 – 60 Hz
Operating temperature range
1,5 – 65 °C
Power interface
3 x 0,75 mm
2
Protection class
IP65
Volume
131cm
3
Mass
560 g
A
77,0 mm
B
64,7 mm
C
58,6 mm
D
38,1 mm
E
32,2 mm
Please take the relevant climate zone into account when dimensioning yours specific application.
Approximate calculation of discharge capacity:
Q = Kvs ×
Δp
× (
)
Q
= Discharge capacity [l/min]
Kvs
= Flow coefficient
Δ
p
= Pressure difference [bar]
Time ON [0,5s-10s] and Time OFF [0,5min-45min] are determined by adjustment knobs.
Time ON
Time ON + Time OFF x 60
√
– 10 –