Design and function
Select welding task
099-005224-EW501
08.11.2011
43
5.10.2.3
Setting the expert parameters
NOTE
The parameter values set are preset in the JOB and can be modified if necessary.
Operating
element
Action Result
1 x
1 x
2 x
Select expert parameters.
The key combination must be pressed within 3 seconds.
Select expert parameters:
Gas pre-flow time "GvS" (0 s to 10 s)
Wire creep speed "On" 0.5 – 24 m/min
Ignition time "tZn" (0 ms to 500 ms)
n x
The selected parameter is shown on the display.
Set the parameter chosen.
5.10.2.4
Explanation of symbols
Symbol Meaning
"GnS" - Gas post-flows
"drb" - Wire burn-back
"t1" - Spot time
"t2" - Interval time
"GvS" - Gas pre-flows
"On" - Wire creep
"tZn" - Ignition time
"tyP" - Machine type (type table, see chapter "Rectifying faults")