Functional characteristics
Machine control – Operating elements
34
Item No.: 099-004934-EWM01
Item Symbol Description
0
MIG spots (parameter selection t1 is carried out using the "Runtime
parameters" button, setting on the "Rotary transducer".
Interval (parameter selection, t1 = pulse time, t2 = pulse pause, carried out
using "Runtime parameter" button, setting on the "Rotary transducer".
"Runtime parameters" button
The parameters are set on the rotary transducer
Gas post-flow time (0.0 s to 10.0 s)
Wire burn-back (-50% to +50%)
Spot time / pulse time (0.1 s to 5.0 s)
7
Pulse pause (0.1 s to 2.0 s)
8
Display, Top
Displays welding voltage or person who designated the runtime parameters
9
Display, Down
Display of wire feed speed, welding current and runtime parameters.
10
Signal light, HOLD
Lit:
Display shows the last parameters used for welding.