Rectifying faults
Checklist for rectifying faults
099-005674-EW501
28.06.2022
53
Warning
Potential cause / remedy
34
JOB unknown
JOB selection was not carried out because the JOB number is
unknown.
35
Excess current on the wire feed
motor slave
Excess current detected on wire feed motor slave (push/push
system or intermediate drive).
36
Slave tacho error
Fault of wire feeder - permanent overload of the wire drive
(push/push system or intermediate drive).
37
FAST bus failure
Wire feeder not connected (reset by actuating the automatic cir-
cuit-breaker of the wire feed motor).
38
Incomplete component infor-
mation
Check the XNET component management.
39
Mains half-wave failure
Check supply voltage.
40
Weak power grid
Check supply voltage.
41
Cooling unit not recognised
Check the cooling unit connection.
47
Battery (remote control, type
BT)
Battery level is low (replace battery)
[1]
only for the XQ machine series
[2]
See technical data for values and other switching thresholds
> see 8.2 chapter
.
7.3 Checklist for rectifying faults
The correct machine equipment for the material and process gas in use is a fundamental
requirement for perfect operation!
Legend
Symbol
Description
Fault/Cause
Remedy
Mains fuse triggers
Mains fuse triggers - unsuitable mains fuse
Set up recommended mains fuse
> see 8.2 chapter
.
Functional errors
Insufficient coolant flow
Check coolant level and refill if necessary
Eliminate kinks in conduit system (hose packages)
Reset automatic cutout of the coolant pump by activating
Air in the coolant circuit
Vent coolant circuit
> see 7.4 chapter
Several parameters cannot be set (machines with access block)
Entry level is blocked, disable access lock
All machine control signal lights are illuminated after switching on
No machine control signal light is illuminated after switching on
No welding power
Phase failure > check mains connection (fuses)
Connection problems
Make control lead connections and check that they are fitted correctly.