Design and function
Remote control
76
099-000109-EW501
23.08.2018
5.6.2
Specifying max. no. of accessible programs
This function can be used to specify the maximum number of programs which can be called up
(only applies to the welding torch). According to the factory setting, all 16 programs can be called
up. If necessary these can be limited to a specific number.
To limit the number of programs, the welding current needs to be set to 0A for the next, unused
program. For example, if only programs 0 to 3 are being used, the welding current is set to 0A in
program 4. A maximum of programs 0 to 3 can then be called up on the welding torch.
5.6.3
Example "Program with synergetic setting"
Figure 5-69
5.6.4
Example "Program with conventional setting"
Figure 5-70
5.6.5
Accessories for switching over programs
The user can change, retrieve and save programs using the following components.
Programs
Component
create and change
call up
Welding machine control
16
16
PC with PC 300 welding parameter soft-
ware
16
16
Tetrix RINT X11, -X12 robot interface
-
16
BUSINT X11 industrial bus interface
-
16
5.7
Remote control
The remote controls are operated on the 19-pole remote control connection socket (analogue).
5.7.1
RT1 19POL
Functions
• Infinitely adjustable welding current (0% to 100%) depending on the preselected
main current on the welding machine.