Design and function
PC interface
099-005649-EW501
19.11.2020
37
5.6.2 RINT X12 robot interface
The standard digital interface for mechanised applications
Functions and signals:
• Digital inputs: start/stop, operating modes, JOB and program selection, inching, gas test
• Analogue inputs: control voltages, e.g. for welding performance, welding current, etc.
• Relay outputs: process signal, ready for welding, system composite fault, etc.
5.6.3 BUSINT X11 industrial bus interface
The solution for easy integration with automated production with e.g.
• Profinet/Profibus
• EnthernetIP/DeviceNet
• EtherCAT
etc.
5.7 PC interface
Equipment damage or faults may occur if the PC is connected incorrectly!
Not using the SECINT X10USB interface results in equipment damage or faults in signal trans-
mission. The PC may be destroyed due to high frequency ignition pulses.
• Interface SECINT X10USB must be connected between the PC and the welding machine!
• The connection must only be made using the cables supplied (do not use any additional ex-
tension cables)!
PC300.Net welding parameter software
Set all welding parameters on the PC and simply transfer to one or more welding machines (accessory,
set consisting of software, interface, connection leads)
• Manage up to 510 JOBs
• Exchange JOBs with the welding machine
• Online data communication
• Default settings for welding data monitoring
• Always up-to-date thanks to standard update function for new welding parameters
• Data backup by easy communication between power source and PC
5.7.1 Connection
Figure 5-18
Item Symbol Description
0
1
Connection socket (9-pole) - D-Sub
PC interface
> see 5.7 chapter
2
Connection cable, 9-pole, serial
3
SECINT X10 USB
4
USB connection
Connecting a Windows PC to SECINT X10 USB
5
Windows PC
5.8 Component identification
These accessory components can be retrofitted as an option
> see 9 chapter
.
Bar codes predefined in ewm Xnet are recorded with a manual scanner. Component data are retrieved
and displayed in the control.