Functional characteristics
Welding programs
32
099-00T500-EW501
2.9.2022
5.2.3.5 Automatic AC frequency
Activation takes place in the functional sequence using the parameter frequency . By turning to the left,
the parameter value is reduced until the parameter
(AC frequency automatic) is shown in the display.
The signal light comes on when the function is enabled.
The machine control takes over the regulation or setting of the alternating current frequency depending
on the set main current. The lower the welding current, the higher the frequency and vice versa. This
achieves a concentrated, directionally stable arc when welding currents are low. The load on the tungsten
electrode is minimised when the welding currents are high ensuring a longer service life.
The use of a foot-operated remote control with this function reduces manual intervention by the user
during the welding process to a minimum.
Figure 5-11
Selection
4s