Design and function
Remote control
42
099-002058-EW501
26.11.2015
5.7.6
Expert menu (MMA)
To change the advanced setting parameters, hold down the "Welding parameters" button for
2 seconds after selecting the welding process.
The following diagram shows the setting options.
ENTER
EXIT
NAVIGATION
2s
2s
Figure 5-18
Display
Setting/selection
Hotstart current
Hotstart current setting (50 % to 200 %)
Hotstart time
Hotstart time setting (0,1 s to 20,0 s)
Arcforce correction (setting -10 to 10, factory setting 0)
• Increase value > harder arc
• Decrease value > softer arc
Pulse current
Setting range 1%
–200%
Balance
Percentage of time from pulse cycle Tpuls for pulse current IP1
Setting range 1%
–99%
5.8
Remote control
The remote controls are operated on the 19-pole remote control connection socket (analogue).
5.8.1
Foot-operated remote control RTF1 19POL
Functions
• Infinitely adjustable welding current (0% to 100%) depending on the preselected
main current on the welding machine.
• Start/stop welding operation (TIG)