Machine description
– quick overview
Machine control
– Operating elements
18
099-002057-EW501
28.04.2014
4.3
Machine control
– Operating elements
Figure 4-3
Item Symbol
Description
0
1
Collective interference signal light
For error messages, see the "Rectifying faults" chapter
2
Excess temperature signal light
In case of excess temperature, temperature monitors de-activate the power unit, and
the excess temperature control lamp comes on. Once the machine has cooled down,
welding can continue without any further measures.
3
VRD
Voltage reduction device (VRD)
The VRD signal light is illuminated, when the voltage reduction device is operating
without fault and the output voltage is reduced to a value specified in the relevant
standard (see technical data). The voltage reduction device is only active on VRD
machine versions.
4
AMP%
Hotstart current signal light
50 % to 200 % of the main current
5
Welding parameter setting rotary transducer
Setting of welding current and other welding parameter and their values
6
sec
Hotstart time signal light (0.1 s to 20 s)
7
Select welding parameters button
This button is used to select the welding parameters depending on the welding process
and operating mode used.
8
AMP
Main current signal light
Imin to Imax (1 A increments)
9
Signal light, MMA pulsed welding
On:
Function switched on
Not on: Function switched off
Flashing:
Parameter selection and frequency setting
PUL: (on) Function switched on/(off) Function switched off
FrE: Frequency setting (0.2 Hz500 Hz, ex works: 1.0 Hz)