Design and function
Special parameters (advanced settings)
099-005403-EW501
10.2.2022
87
Display
Setting/selection
Program settings for relative programs
0 = --------Combined setting of relative programs possible (ex works).
1 = --------Individual setting of relative programs possible (ex works).
Correction or nominal voltage display
0 = --------Correction voltage display (ex works).
1 = --------Absolute nominal voltage display.
JOB-Selection with Expert operating mode
> see 5.11.3.23 chapter
0 = --------SP1-SP3 Switching on the wire feeder if the machine has an expert control (ex
works)
1 = --------JOB selection of wire feeder possible
Nominal value of wire spool heater (OW WHS)
> see 5.11.3.24 chapter
off = switched off
Temperature setting range: 25°C - 50°C (45°C ex works)
Operating mode switching at welding start
> see 5.11.3.25 chapter
0 = --------Not enabled (ex works)
1 = --------Enabled
Error threshold of electronic gas flow control
> see 5.11.3.26 chapter
Error output in case of gas nominal value deviation
Unit system
> see 5.11.3.27 chapter
0 = --------metric system (ex works)
1 = --------Imperial system
Selection option for program sequence with rotary knob
> see 5.11.3.28 chapter
0 = --------Not enabled
1 = --------Enabled (ex works)
5.11.2 Reset to factory settings
All special parameters saved by the user will be overwritten by the factory settings!
l
0
l
0
Figure 5-80
5.11.3 Special parameters in detail
5.11.3.1 Ramp time for wire inching (P1)
The wire inching starts with a speed 1.0 m/min for 2 secs. It is subsequently increased to a ramp function
to 6.0 m/min. The ramp time can be set between two ranges.
During wire inching, the speed can be changed by means of the welding power rotary knob. Changing the
speed has no effect on the ramp time.