Machine description
– quick overview
Machine control
– Operating elements
18
099-007010-EW501
07.09.2016
3.3
Machine control
– Operating elements
Figure 3-4
Item Symbol
Description
0
1
Operating mode rotary switch
------ not available
-- Operating mode non-latched
------ Operating mode non-latched with Up- and Downslope
---- Operating mode latched with Up- und Downslope
2
Excess temperature signal light / Welding torch cooling failure
For error messages
> see 6 chapter
3
Ignition current
Setting range 0% to 100% depending on the main current.
4
Rotary dial Upslope time
Setting range 0 s to 25 s
5
Torch trigger signal light
Illuminates immediately torch trigger 1 is activated.
6
Welding current setting rotary dial
Infinite setting of the welding current across the whole power range.
7
Rotary dial Downslope time
Setting range 0 s to 25 s
8
Rotary dial Secondary current
Setting range 1% to 100% depending on the main current.
9
Gas post-flow time dial
Setting range 0 s to 20 s