Design and function
Access control
36
099-005637-EW501
27.04.2021
5.8 Access control
To protect against unauthorised or unintentional adjustment of the welding parameters on the machine,
the control input can be locked with the aid of a key switch.
In key switch position 1 all functions and parameters can be set without restriction.
In key switch position 0 the following functions and parameters cannot be changed:
• No adjustment of the operating point (welding performance) in programs 1–15.
• No change of welding or operating mode in programs 1–15.
• The welding parameters can be displayed but not changed in the control's function sequence.
• No welding task switching (JOB block operation P16 possible).
• No change of special parameters (except P10). Restart required.
5.9 Interfaces for automation
WARNING
Do not carry out any unauthorised repairs or modifications!
To avoid injury and equipment damage, the unit must only be repaired or modified by
specialist, skilled persons!
The warranty becomes null and void in the event of unauthorised interference.
• Appoint only skilled persons for repair work (trained service personnel)!
Accessory components and the power source itself can be damaged by incorrect connection!
• Only insert and lock accessory components into the relevant connection socket when the
machine is switched off.
• Comprehensive descriptions can be found in the operating instructions for the relevant ac-
cessory components.
• Accessory components are detected automatically after the power source is switched on.