EWELLY EW-986B Manual Download Page 2

        Mode

EW-986B

  K-Thermocouple 

Sensor

load

10A/220V/AC

Wiring diagram

Parameters for Procedure

Warnings

1. Please read this product instruction carefully and connect 

input/output plugs of power & sensor to the  corresponding sockets 

strictly by following connection diagram, otherwise the usage & 

operations will   be affected. Check again to make sure there is no 

mistake. Tighten all the screw of connection plugs aga in, and then 

connect it to the power for running.

2. Keep away this product from moist or corrosiIve air and high 

magnetic field. Otherwise the normal  operaton of this product will 

be affected.
.

3. All our products have passed strict quality inspections before 

leaving factory. We provide one-year quality guarantee (which is 

limited to product itself) period for this product.

    If you have any doubt or problem concerning the 

electronic temperature or humidity controller made by 

us, please contact our distributors and we will provide 

you high-quality after-sale services. Thanks!

About Failure

Failure

No display when power 

is on.

Displayed temperature is

unstable or there exists 

misplay..

EI

 is displayed

The sensor wiring is short circuit or 
open circuit.

Check to see if the sensor wiring has good contact 
with coupling end or not.

Check to see if the power is short circuit.

The thermostat fails.

The set temperature is higher than the present
 temperature.
The heat protector is open circuit because the 
 pressure is over loads.

The sensor wiring is interfered, poorly contacted or

is tied with other cables. The current is light because 

of damage  in the wiring.

The locations for the sensors are not correct or 
sensor wiring is too long and its resistance is too 
big. The wiring contact is poor and the sensor`s 
damag.

The sensor is not correctly installed and cannot
 measure the correct temperature. Compressor 
contactor fails.

Check power supply and change fuse.

Check if there is 220V power input or change 

 thermostat with our distributor.

Reset the necessary controlling temperature.
Check the reasons for overload and overheating. 
 After the trouble is solved, restart to work.

Separate sensor wiring with power cables or change 

shielded lines or check if the contact is tight or not.

All sensors should be corrected at their locations. 

Enlarge the cross section of the expanded wires. 

Make sure the wiring sealing, is good. 

Change sensor.

Check if the sensor has accurately measured the

 temperature or not. Change compressor contactor.

Causes

Precautions

Difference with temperat-
ure within storage and the
displayed temperature is
too big.

Machine does not stop 
when the temperature
reaches.

Machine does not work 

but display exits

Guangzhou Eliweli Autocontrol Tech. 

Co., Ltd.

        

220V/AC

2 3 4 5 6 7 8 9

10

1

-

Load

1~15

 

15

15

0~400

0~3

00

50

5

1

400

0

Setting range

Alarm on lowlimit

Temperature

Alarm on high limit

Temperature

Delayed Time

Min

Temperature 
Correction

Temperature Return 

Difference

Setting Range

Function

Unit

Ex-factory Value

0

℃~

control

 

temperature-1

             

control 

 

tempera-

ture+1

℃~

400

   

Feature

 

descriptions

Note:When a high temperature alarm settings should be greater 

than the set temperature and hysteresis sum

When you set the temperature alarm should be less than the set 

temperature minus the hysteresis sum.

Heating system: When the current temperature 

the setting 

temperature - the temperature hysteresis and delay the 

setting of the "delay time", the load relay Off.

Heating system to stop: when the current temperature 

≥ 

setting temperature, the load relay is disconnected.