Ewellix TLC 12ZWAK Installation, Operation And Maintenance Manual Download Page 6

6

Teles c op ic  pillar TLC

6

2.0  Safety

This chapter targets all the users of the TLC telescopic pillar. 
It contains information on its safe use and optimal utilization.

2.1  Safety program

The safety program from Ewellix spells out who is entitled to 
use it and the responsibility of individual users.

The TLC was designed and built in accordance with the lat-
est technical standards and accepted safety rules.

EU-conformity is documented with the technical 
documentation.

2.1.1  Purpose of use of the TLC

The telescopic pillar TLC has been designed and built to be 
operated in accordance with its intended use. If you use the 
TLC for any use other than that cited, the manufacturer can-
not be held responsible for damage resulting from this.

The TLC has been specifically designed for the movement of 
patient tables, instrument carriers, instrument tables, small 
lifting tables and dentist's chairs.

2.1.2  Intended Use

The intended use of the TLC is:

•  dynamic, compression or tension loaded stroke. 

NOTE

Please note:For the operations data, please see the Appendix of 

this operating manual (⮑7.0 Appendix, page 16).

2.1.3  Unauthorized use

Any use other than the intended use without the manufactur-
er's written agreement or operation beyond the technical 
limits is considered unauthorized.

You can find the technical operating limits in the Appendix 
(⮑7.0 Appendix, page 16) of this manual and on the type 
plate of the TLC. 

NOTE

Please note: Any unauthorized use of the TLC can cause personal 

injury and property damage. Always adhere to the instructions of 

this manual.

2.1.4  User groups

To ensure safety, we place requirements on the users of the 
TLC, that must be adhered to under all circumstances. Only 
persons who meet the requirements are entitled to use the 
TLC.

We refer to all persons who operate, use, commission the 
telescopic pillar, process it further or pass it on for further 
processing as user groups. As the requirements of these 
user groups strongly depend on their role, we distinguish 
between the following user groups:

The 

operating authority

 iis the contractual partner of the 

person doing the further processing or the reseller. They can 
impose legal conditions on the operating authority when 
purchasing the telescopic pillar. The operating authority en-
sures that the user is instructed in the authorized use of the 
equipment.

The 

processor

 is the contractual partner of the reseller or 

the manufacturer. He assembles the telescopic pillar into a 
complete device. He is authorized by the manufacturer to 
use the telescopic pillar TLC in accordance with the regul-
tions and has the necessary expert knowledge.

The 

technician

 has the professional technical training to 

utilize the telescopic pillar TLC according to its authorized 
use. Apart from the chapter on Safety, he is also familiar 
with the chapter on Special operating modes. He will find 
the required technical data in the Appendix.

The 

reseller

 forwards the machine.

Summary of Contents for TLC 12ZWAK

Page 1: ...CATEGORY MAX 2 LINES INSTALLATION OPERATION AND MAINTENANCE MANUAL TLC Telescopic pillar...

Page 2: ......

Page 3: ...zones 7 2 1 7 Areas of responsibility 7 2 1 8 General safety notice 7 2 2 Other hazards 8 3 0 Function 9 3 1 General function 9 3 2 Correct use 9 3 3 Ambient conditions 9 3 3 1 Operation 9 3 3 2 Stora...

Page 4: ...2 Explanation of symbols and signal words Safety precautions Safety precautions in this manual are identified by symbols and signal words These signal words shown to the right in dicates the severity...

Page 5: ...The infor mation therein is organized into four task and theme related parts The Basic Principles section gives the basic knowledge that every user should have The Normal Operation section contains i...

Page 6: ...this manual and on the type plate of the TLC NOTE Please note Any unauthorized use of the TLC can cause personal injury and property damage Always adhere to the instructions of this manual 2 1 4 User...

Page 7: ...structing the user groups Complying with all relevant legal conditions and regula tions NOTE Please note The Operating Authority may only authorize persons to use the TLC who meet the requirements for...

Page 8: ...escopic pillar WARNING Warning of side acting forces Excessive side acting forces destroy the pillar and pose a danger to persons During the stroke do not manipulate any of the elements that are conne...

Page 9: ...direction of load when ordering The unit must not be converted or modified CAUTION Where eccentric loads are involved the permissible maximum load decreases Please observe the permissible load on the...

Page 10: ...by external pneu matic control devices an electrical cable via which the mo tor s direction of rotation is controlled externally or via a low voltage interface using an electrical handswitch or foots...

Page 11: ...ctions NOTE Protection class I applies for the TLC The external and internal aluminium tubes have a protective conductor connection Fig 1 A A For top connection Always lock the plug at the bottom usin...

Page 12: ...or the customer s own plates Remove the transportation screws 4 pcs Fasten the mounting plates onto the aluminium tubes using the four bores auxiliary plates are fitted to the end faces of the outer t...

Page 13: ...han one TLC may be used for parallel operation Never connect multiple actuators to a single two way contact The operating speed is a function of the load Where loads are uneven the actuators can buckl...

Page 14: ...es depending on the requirements 4 1 2 Accessories page 11 5 1 Controlling an actuator The actuator is controlled in accordance with the connection diagram 4 2 1 Connecting the power cable control dev...

Page 15: ...can permanently damage the metal and plastic com ponents of the actuator High pressure steam cleansing equipment must not be used 6 3 Warranty Assuming that the operating conditions are complied with...

Page 16: ...16 Telescopic pillar TLC 7 0 Appendix Technical Data Sheet PUB IL 07010 EN October 2019 Telescopic pillar TLC For further technical information please contact Ewellix...

Page 17: ...100 to 700 100 to 700 255 to 700 255 to 700 Retracted length push version mm S 175 S 175 S 60 S 60 Retracted length pull version mm S 185 S 185 S 70 S 70 Voltage V AC 120 or 230 120 or 230 120 or 230...

Page 18: ...included To be ordered separately Legend S stroke L retracted length 220 190 101 200 170 101 15 20 11 22 Retracted length 2 Stroke 2 4xM10x30 4xM10x30 220 190 129 200 170 129 15 11 22 Supporting plate...

Page 19: ...ction Load distance from center of pillar mm Load distance from center of pillar mm Load N 300 400 500 600 700 Overload range Overload range Ideal load range Ideal load range Under load range Under lo...

Page 20: ...mm 4 500 mm 5 600 mm 6 700 mm 7 T L C 1 2 W 0 Options written in yellow are only available on demand Contact Ewellix for more information on minimum quantities and additional costs Ordering key Desig...

Page 21: ......

Page 22: ...en taken in the production of this catalog Ewellix does not take any responsibility for damage or other loss resulting from omissions or ty pographical errors The photo may differ slightly in appearan...

Reviews: