background image

WIRING

ST-3E

R1

B

R

O

W

G

C

ZONE1
T’STAT

Y

R

G

O/B

W/E

C

ZONE
T’STAT

 NCM-300

Gas/Elec. 1H/1C

C

RH/B

Y

G

R

W

RC/O

E

W

T

-3

6

1

1

C

RH/B

Y

G

R

W

RC/O

E

W

T

-3

6

1

1

Y

NON-ZONED

GAS OR OIL

1 HEAT/ 1 COOL

NON-ZONED

HYDRO OR OIL

C

RH/B

Y

G

R

W

RC/O

E

W

T

-3

6

1

1

C

RH/B

R

W

G

C

RC/O

E

W

T

-3

6

1

1

Y

G

R

W

1 HEAT/ 1 COOL

AIR HANDLER

Y

R

W

C

ZONE2
T’STAT

Y

C

RH/B

Y

G

R

W

RC/O

E

W

T

-3

6

1

1

COMPRESSOR

Y

G

R

W

Y

C

GAS FURNACE

C

T

T

TO

BOILER OR

CIRCULATOR CONTROL

EWC Controls Inc.   385 Highway 33   Englishtown, NJ 07726   800-446-3110   FAX 732-446-5362     E-Mail- [email protected]

3

Copyright © 2009 EWC Controls All Rights Reserved

ISOLATION CIRCUIT
        REQUIRED

NO ISOLATION CIRCUIT
          REQUIRED

Jumper

NON-ZONED

HEAT PUMP

C

RH/B

Y

G

R

W

RC/O

E

W

T

-3

6

1

1

R

W

G

C

1 HEAT/ 1 COOL

HEAT

PUMP

Y

Figure 5

Figure 6

Figure 7

Figure 8

Figure 9

R

O

G

C

Y

AIR HANDLER

This thermostat model 

does not

 have auxiliary or emergency

 heat features, therefore it cannot be used on heat pump 
systems that require these functions.

Summary of Contents for EWT-3611

Page 1: ...Hz 1 0 Amp Max load per terminal Thermal Ratings Set point Temperature Range 45 F to 95 F Operating Ambient Temperature 30 F to 99 F Storage Temperature Range 14 F to 140 F ATTENTION This product does not contain mercury However this product may replace a unit which contains mercury EWC Controls Inc would like to advise all technicians and consumers that all mercury thermostats should be recycled ...

Page 2: ...r this switch is in the STD position Leave it in this position if you have ANY system that uses gas oil electric or hot water heating If you have a single stage Heat Pump the thermostat can be configured to the Heat Pump mode by moving the switch to the HP position This thermostat model does not have auxiliary or emergency heat features therefore it cannot be used on heat pump systems that require...

Page 3: ...C GAS FURNACE C T T TO BOILER OR CIRCULATOR CONTROL EWC Controls Inc 385 Highway 33 Englishtown NJ 07726 800 446 3110 FAX 732 446 5362 E Mail info ewccontrols com 3 Copyright 2009 EWC Controls All Rights Reserved ISOLATION CIRCUIT REQUIRED NO ISOLATION CIRCUIT REQUIRED Jumper NON ZONED HEAT PUMP C RH B Y G R W RC O EWT 3611 R W G C 1 HEAT 1 COOL HEAT PUMP Y Figure 5 Figure 6 Figure 7 Figure 8 Figu...

Page 4: ...in COOL Setting New Set Point Temperature Press either or once and display the set point temperature Press either or again to change your desired set point temperature Hold the key down for over 2 seconds to fast advance the set point temperature Auto Shut Off Your thermostat will automatically shut off in HEAT mode if the room temperature rises above 95 F 35 C It will shut off in COOL mode if the...

Reviews: