Page | 3 User manual for evplug charger 3.6 kW PN. EV30001
www.evplugchargers.com
only and is NOT transferable.
PLEASE NOTE:
This document includes the
latest information at the time of printing.
EVplug Chargers, S.L. reserves the right to
make changes to this product without
further notice. Changes or modifications to
this product by other than an authorized
service facility could void the product
warranty
Failure mode:
Failure mode identifies that there is an error in the upload process.
It can occur for the following reasons:
1. Differential protection: Error in the ground connection, connector, cables or very
humid or wet vehicle battery.
2. High or low voltage: the supply voltage is too high or too low.
3. Temperature above or below the working limits.
4. High current or short circuit in charging circuit.
In the event of this error, unplug the charger and reconnect it. In case the error persists,
contact an authorized electrical installer.
Green (1 flash) Green (2 flash)
Green (3 flash) Red Fault
Initial Mode
On
Off
Off
Off
Waiting conection
On
Flash (1s)
Off
Off
Charging mode
Flashing
Flashing
Flashing
Off
Charging Complete On
On
On
Off
Fault Mode
Off
Off
Off
On
LED Display Status Code
Condition