Failure mode: 

Failure mode identifies that there is an error in the upload process. 
It can occur for the following reasons: 
1. Differential protection: Error in the ground connection, connector, cables or very 
humid or wet vehicle battery. 
2. High or low voltage: the supply voltage is too high or too low. 
3. Temperature above or below the working limits. 
4. High current or short circuit in charging circuit. 
 
In the event of this error, unplug the charger and reconnect it. In case the error persists, 
contact an authorized electrical installer.

 

Green (1 flash) Green (2 flash)

Green (3 flash) Red Fault

Initial Mode

On

Off

Off

Off

Waiting conection

On

Flash (1s)

Off

Off

Charging mode

Flashing

Flashing

Flashing

Off

Charging Complete On

On

On

Off

Fault Mode

Off

Off

Off

On

LED Display Status Code