EVOVX EVOAQ Installation Instructions Download Page 4

This controller has been designed to only work with EVOVX Ventilation System EC 

Fans

Set Temperature Range:
Temperature Resolution:

Operating Voltage/Frequency: 

Sensing Element:
Operating Temperature:

Operating Humidity:

Output Control:

Display: 
Approval:

 

EMC Approval:

5 - 35°C
0.5°C
12 - 24 Volt DC 

NTC thermistor
0 to 40ºC

5 - 90% non-condensing

Digital control interface

3.5” digital LCD Touchscreen
All relevant AS/NZS standards
All relevant AS/NZS standards

Technical Specifications

Advanced controller functions

• 

Turn off your controller with the Power Off        button.

• 

Press and hold the Ventilation rate adjust        button for 5 seconds.

• 

Release the button when the screen turns on.

To calibrate your controller's room temperature you need to enter the programming mode

• 

Press the Power Off        button to return to the home screen.

The temperature calibration value is shown in the middle of the display. Adjust the calibration 
value using the Adjust Up       and Down       buttons.

• 

The controller will turn off after 5 seconds of no activity in programming mode.

 

The 

calibration value is added or subtracted (if negative) to the room temperature.

 

Example: 

The room temperature is 22°C and the controller displays 20°C.  The 

calibration value is -1°C 

          

change the calibration value to 1°C.

• 

To lock the controller press and hold the Adjust Up       and Down       buttons together.

• 

The Lock Symbol        appears in the middle-left of the display.

• 

To unlock the controller repeat as above.

Locking the controller

The unit should be checked and the filter changed  at least every 24 months.

Page 4

V1.1:20181005