Ionization Smoke Alarm/detector for EVOLVEO Sonix
I. Features
Ceiling or wall mounting
Easy to install with mounting hardware included
9Volt battery operated (included)
Suitable for any room
Test button for easy recommended monthly testing
Low battery signal
Safety clip feature, not allow mounting of smoke alarm without battery installed
Ionization chamber for early detection from all directions
Loud 85DB alarm signal
Specifications
Power Supply: 9V battery
Operating Current: 10uA(normal) and 20-50mA(alarm working)
Sensitivity of smoke detector: In comply with UL217 Standard
BS5446: Part 1 2000
Kite mark License no. KM 53166
0.8-1.42%/FT
Operating Temperature:40
℉
-100
℉
(4.4
℃
-37.8
℃
)
Ambient Humidity: 10%-90%
Horn Level : 85 Decibels at 10 feet
Battery life:1 year min.
Size:106mmX30mm
Box size:48X42X33.5CM
Weight: 0.13kg/pc; 17.3kg/box;
Packing: 132pcs/Box, one pc/small box, single.
CE APPROVAL
II. Compliant and Installation
Choose a right place to install
Dig a hole in the installed location according to the position.
Then put plastic nails and fix the bracket into the wall.
Fix the smoke detector and make sure it is connected with bracket properly.
Smoke detector is suitable to be installed in bedroom, kitchen, garage, base room and etc.
The best installation is the center between bedroom and living room for you don’t expect the right position of fire
If being installed in, it should be less than 4 meters of height of wall.
If being installed in the wall, the distance between the wall and ceiling should be 10cm to 20cm.
When being installed, smoke detector should not be installed next to door, window where there is too much floating air in order not to
affect Sensitivity of smoke detector.
The quantity per unit area: one in 10—20 square meters. In special location, one per 2.5meters.
Don’t install it in the wet place such as bathroom, top floor and etc.
III. Guide of use.
After power inputting, it will work and the
indicated
LED flashes once every 2 minutes. It will alarm when checking smoke unit the smoke
is disappeared.
When working with alarm system together, you can press the test button to make sure it can check code with control system.
The solution to the following problem:
Don’t alarm when pressing the button, please check if the power on or off.
Don’t alarm when test it with smoke, please clean the smoke detector.
Indicated
LED doesn’t flash, please contact professional maintenance man.
IV. Checking and Maintenance
Keep 3 more seconds when testing its quality, the smoke detector will alarm with clear and sound; and LED flashes normally, smoke
detector sends out alarm signal. You also can put the smoke into smoke detector for test.
You’d better test once every week to make sure it works normally. At least once a month.
Please replace the battery as soon as possible when LED is always on which means power is not enough, need to be recharge.
Clean the smoke detector every 6 months. Cut electricity first and then clean the dust with soft brash.
It is forbidden to clean with water or wet inside.
Don’t break or separate the smoke detector.
NOTE: Only professional maintenance man can open smoke detector.