background image

13

www.evolutionpowertools.com

EN

WARNING: Mag Drills must not be connected to a power 
source until all assembly and preparation has been 
completed and a safety check carried out.  Evolution Mag 
Drills should only to be used on non-coated Mild Steel which 
is free from paint or loose rust etc. 

Remove the machine from the case and check that all accessories 
are present and correct. 

WARNING:

 All Magnetic Drilling machines are heavy. Enlist 

competent help when lifting these machines.

•    Place the machine onto a clean, sturdy work surface.
•  Attach the three handles into the spindle hub ensuring that they 

are fully seated. 

(Fig. 1)

•  Attach the Safety Guard and secure in place using the supplied 

fixing screws. 

(Fig. 2)

•  Attach the coolant/lubrication bottle to its service position. Use 

the tapped hole located at the top left of the machines casing 
and the Ø6 screw (provided). 

(Fig. 3)

•  Insert the ‘free’ end of the supply tube into the ‘quick connector’.

Note:

 

To release the delivery tube from the quick connector 

(Abb.3a)

 push the collar towards the brass union and withdraw 

the delivery tube.

Note:

 For some operations it may be convenient to remove the 

coolant/lubricant bottle and supply tube and use alternative 
methods of coolant or lubricant application.

TESTING - All Evolution Magnetic Drilling Machines

WARNING:

 

All Evolution Magnetic Drilling machines have Class 

1 insulation and must be earthed. Any power socket that this 
machine is connected to must be grounded to earth. Ensure 
that both operating switches are in the ‘OFF’ position before 
connecting the power cord to the socket.

WARNING: 

The power cord assembly is a custom terminated one. 

Replacement should only be carried out by a qualified technician. 
Use only replacement parts recommended by Evolution Power 
Tools. 

WARNING:

 

Do not perform any testing with a cutter or drill 

installed in the machine.
  
•  Place the machine onto a piece of clean 10 mm thick mild steel 

plate that is larger than the magnetic base of the machine.

•  Connect the plug into a mains supply outlet and switch on the 

socket (UK only).

•  Operate the rocker switch on the machines switch panel to 

energise the magnet. 

(Fig. 4)

ASSEMBLY AND PREPARATION

Fig. 1

Fig. 3

Fig. 2

Fig. 3a

Summary of Contents for S28MAG

Page 1: ...Date Published 23 07 2019 Written in UK English Original Instructions S42MAG shown without guards fitted for illustrative purposes only S42MAG S28MAG...

Page 2: ...Power Tools will within the guarantee period and from the original date of purchase repair or replace any goods found to be defective in materials or workmanship This guarantee is void if the tool bei...

Page 3: ...apacity 13mm 1 2 13mm 1 2 MAGNET Magnetic Adhesion 1300kg f 2860lbs f 1300kg f 2860lbs f Minimum Plate Thickness 10mm 3 8 10mm 3 8 DIMENSIONS Magnet Dimension 40 x 90 x 180mm 1 5 8 x 3 1 2 x 7 1 8 40...

Page 4: ...immediate medical advice The measurement and assessment of human exposure to hand transmitted vibration in the workplace is given in BS EN62841 1 2015 Many factors can influence the actual vibration...

Page 5: ...position provided the magnetic adhesion and work environment allow WARNING To prevent ingress of fluids into the electrical system cutting paste should be used rather than cutting fluid when using th...

Page 6: ...njury Save all warnings and instructions for future reference The term power tool in the warnings refers to your mains operated corded power tool or battery operated cordless power tool 1 General Powe...

Page 7: ...r Tool Safety Warnings Power tool use and care a Do not force the power tool Use the correct power tool for your application The correct power tool will do the job better and safer at a rate for which...

Page 8: ...y of the mains power supply Ensure that this machine has a dedicated power supply and use a lock on device to ensure that the mains power supply cannot be interrupted or compromised accidentally Do no...

Page 9: ...the main slide upwards until its top edge is level with the top of the dovetail slide way Turn the upper adjusting screw to take up any free movement Operate the crank handle to move the slide up and...

Page 10: ...magnet base on this power tool can deactivate if the power supply is interrupted or suffers an electrical malfunction To prevent possible operator injury the safety strap or chain supplied should be u...

Page 11: ...th this machine the following accessories are available from Evolution s online shop at www evolutionpowertools com or from your local retailer Description Part No Chuck Adaptor HTA 47 Chuck Chuck Key...

Page 12: ...CUTTER 1 Magnet On Off Switch 2 Motor On Off Switch 3 Guard 4 Annular Cutter Not included 5 Secondary Slide Locking Lever 6 Safety Strap 7 Coolant Tank 8 Spindle Hub And Feed Handles MACHINE FITTED WI...

Page 13: ...ctor Abb 3a push the collar towards the brass union and withdraw the delivery tube Note For some operations it may be convenient to remove the coolant lubricant bottle and supply tube and use alternat...

Page 14: ...CUTTER All Evolution Machines Select a suitable cutter for the required task Check that the cutter is sharp and is not damaged in any way Damaged or dull cutters should not be used WARNING Annular cut...

Page 15: ...crew TO INSTALL AND REMOVE A DRILL BIT Hold the new drill bit with your thumb and index finger then insert it into the chuck Twist the chuck to tighten the drill bit into place If your chuck has a key...

Page 16: ...d flow required Note Sometimes the position of the machine on the workpiece or when a 3 jaw chuck is fitted makes delivery of coolant lubricant impossible If this is the case a suitable cutting compou...

Page 17: ...orrectly position the machine on the workpiece with the electromagnet energised and the safety chain strap securely in place Check for sufficient coolant lubricant flow at the cutter Start the motor b...

Page 18: ...machines main slide Fig 15 Use hex key supplied to loosen slightly the locking screws which lock the adjustable Gib in place Use a hex key supplied and starting with the lowest adjusting screw turn th...

Page 19: ...odel Number 230 240V 095 0001 095 0004 110V 095 0002 Brand EVOLUTION Voltage S28MAG 110V 220 240V 50Hz S42MAG 110V 230 240V 50Hz Input 1200W The technical documentation required to demonstrate that th...

Page 20: ...22 www evolutionpowertools com NOTES...

Page 21: ...23 www evolutionpowertools com NOTES...

Page 22: ...the QR code Right UK Evolution Power Tools Ltd Venture One Longacre Close Holbrook Industrial Estate Sheffield S20 3FR 44 0 114 251 1022 US Evolution Power Tools LLC 8363 Research Drive Davenport Iow...

Reviews: