3) General Power Tool Safety warnings 
[Personal Safety].

a) Stay alert, watch what you are doing 
and use common sense when operating 
a power tool.

 Do not use a power tool 

while you are tired or under the influence of 
drugs, alcohol or medication. A moment of 
inattention while operating power tools may 
result in serious personal injury.

b) use personal protective equipment. 
Always wear eye protection. 

Protective 

equipment such as dust masks, non-skid 
safety shoes, hard hat or hearing protection 
used for appropriate conditions will reduce 
personal injuries.

c) Prevent unintentional starting. 

Ensure 

the switch is in the off-position before 
connecting to power source and or battery 
pack, picking up or carrying the tool. Carrying 
power tools with your finger on the switch 
or energising the power tools that have the 
switch on invites accidents.

d) remove any adjusting key or wrench 
before turning the power tool on. 

 A 

wrench or key left attached to a rotating part 
of a power tool may result in personal injury.

e) do not overreach. 

Keep proper footing and 

balance at all times. This enables better control 
of the power tool in unexpected situations.

f) dress properly. 

Do not wear loose clothing 

or jewellery. Keep your hair, clothing and gloves 
away from moving parts. Loose clothes, jewellery 
or long hair can be caught in moving parts.

g) If devices are provided for the 
connection of dust extraction and 
collection facilities, ensure that these are 
connected and properly used. 

Use of dust 

collection can reduce dust-related hazards.

4) General Power Tool Safety warnings 
[Power tool use and care].

a)  do not force the power tool. use the 
correct power tool for your application. 

The correct power tool will do the job better 
and safer at a rate for which it was designed.

b) do not use the power tool if the switch 
does not turn it on or off. 

Any power tool 

that cannot be controlled with the switch is 
dangerous and must be repaired.

c) disconnect the power tool from the 
power source and/or battery pack from 
the power tool before making any 
adjustments, changing accessories, or 
storing power tools. 

Such preventative 

safety measures reduce the risk of starting the 
power tool accidentally.

d) Store idle power tools out of the reach 
of children and do not allow persons 
unfamiliar with the power tool or these 
instructions to operate the power tool.  

Power tools are dangerous in the hands of 
untrained users.

e) Maintain power tools. 

Check for 

misalignment or binding of moving parts, 
breakage of moving parts and any other 
condition that may affect the power tool’s 
operation. If damaged, have the power tool 
repaired before use. Many accidents are 
caused by poorly maintained power tools.

f) Keep cutting tools sharp and clean. 

Properly maintained cutting tools with sharp 
cutting edges are less likely to bind and are 
easier to control.

g) use the power tool, accessories and 
tool bits etc. in accordance with these 
instructions, taking into account the 
working conditions and the work to 
be performed. 

Use of the power tool for 

operations different from those intended 
could result in a hazardous situation.

Summary of Contents for EvoSaw 230

Page 1: ...Date Published 01 02 2014 Written in UK English V1 Original Instructions EN ES FR SAW230 ...

Page 2: ......

Page 3: ...EN ES FR EN ENGLISH Original Instructions ...

Page 4: ...ower Tool Page 8 SAFETY PRECAUTIONS Electrical Safety Page 9 Outdoor Use Page 9 General Power Tool Safety Instructions Page 9 Additional Safety Instructions Page 11 GETTING STARTED Unpacking Page 13 Machine Overview Page 14 Assembly and Preparation Page 15 Operating Instructions Page 15 MAINTENANCE Environmental Protection Page 21 DECLARATION of CONFORMITY Page 22 English Page 2 Español Página 24 ...

Page 5: ...n Power Tools will within the guarantee period and from the original date of purchase repair or replace any goods found to be defective in materials or workmanship This guarantee is void if the tool being returned has been used beyond the recommendations in the Instruction Manual or if the machine has been damaged by accident neglect or improper service This guarantee does not apply to machines an...

Page 6: ...ric Imperial Motor USA 120v 60Hz 1750W 15A Motor UK EU 230v 50 60Hz 1750W 8A Motor UK 110v 50 60Hz 1750W 15A Speed No Load 2700min 1 2700rpm Weight 8 6kg 19lbs BLADE Mild Steel Blade Metric Imperial Diameter 230mm 9 Bore 25 4mm 1 Number of Teeth Supplied Blade 48 48 Kerf 2mm 078 Speed 3000min 1 3000rpm Noise Vibration Data Sound Pressure LPA Under Load 108 7dB A K 3dB A Sound Power Level LWA Under...

Page 7: ...ring operation e g the work surfaces condition and orientation and the type and condition of the machine being used Before each use such factors should be assessed and where possible appropriate working practices adopted Managing these factors can help reduce the effects of vibration Handling Handle the machine with care allowing the machine to do the work Avoid using excessive physical effort on ...

Page 8: ...Aluminium blade change recommended StainlessSteel bladechangerecommended Lumber blade change recommended PROHIBITED USE OF THIS POWER TOOL WARNING This product is a Steel Cutting Hand Held Circular Saw and must only be used as such It must not be modified in any way or used to power any other equipment or drive any other accessories other than those mentioned in this Instruction Manual WARNING Thi...

Page 9: ...or battery operated cordless power tool 1 General Power Tool Safety Warnings Work area safety a Keep work area clean and well lit Cluttered or dark areas invite accidents b Do not operate power tools in explosive atmospheres such as in the presence of flammable liquids gasses or dust Power tools create sparks which may ignite the dust or fumes c Keep children and bystanders away while operating po...

Page 10: ...at these are connected and properly used Use of dust collection can reduce dust related hazards 4 General Power Tool Safety Warnings Power tool use and care a Do not force the power tool Use the correct power tool for your application The correct power tool will do the job better and safer at a rate for which it was designed b Do not use the power tool if the switch does not turn it on or off Any ...

Page 11: ...bjects being thrown towards your eyes which could result in severe eye damage Before beginning power tool operation always wear safety goggles or safety glasses with side shield or a full face shield where needed ADDITIONAL SAFETY INSTRUCTIONS a DANGER Keep hands away from cutting area and the blade Keep your second hand on auxiliary handle or motor housing If both hands are holding the saw they c...

Page 12: ... If saw blade is binding it may walk up or kickback from the workpiece as the saw is restarted d Support large panels to minimise the risk of blade pinching and kickback Large panels tend to sag under their own weight Supports must be placed under the panel on both sides near the line of cut and near the edge of the panel e Blade depth and bevel adjusting locking levers must be tight and secure be...

Page 13: ...ake care when unpacking Remove the machine together with the accessories supplied from the packaging Check carefully to ensure that the machine is in good condition and account for all the accessories listed in this manual Also make sure that all the accessories are complete If any parts are found to be missing the machine and its accessories should be returned together in their original packaging...

Page 14: ...14 www evolutionpowertools com MACHINE OVERVIEW 1 ON OFF TRIGGER SWITCH 2 AUXILIARY FRONT HANDLE 3 LASER ON OFF SWITCH 4 LASER BATTERY COMPARTMENT 5 LOWER BLADE GUARD 6 FITTED BLADE IN SITU 1 2 3 4 5 6 ...

Page 15: ...tion with the machine disconnected from the power supply Note It is recommended that the operator considers wearing protective gloves when handling the blade during installation or when changing the machine s blade Place saw on a level secure surface Remove the chip collector from the machine by undoing the large thumb screw Fig 1 Note The chip collector thumb screw is captive and cannot be remove...

Page 16: ...ecurelytighten thethumb screw Check that the arbor lock is fully released by manually rotating the blade Replace the wrench and secure it into the base plate using the thumb screw Replace the parallel edge guide if required Parallel Edge Guide A parallel guide for help when rip cutting can be fitted to the base plate of the machine The guide s arms should be inserted into the rectangular slots in ...

Page 17: ...to lock in the required position Adjustment of the Cutting Angle Loosen the bevel locking screw found at the front of the saw Loosen the rear bevel locking screw found at the rear of the machine s base plate Tilt the blade to the required angle Fig 9 Tighten both bevel locking screws securely Note An angle scale 0 450 is incorporated into the bevel locking quadrant to aid setting OPERATING ADVICE ...

Page 18: ...r intervals When cutting steel the chip collector can become hot Care must be taken when handling the chip collector To remove and empty the chip collector Loosen the chip collector thumb screw Ease the chip collector from the machine Empty the contents of the chip collector by tipping the collector and machine upside down over a suitable waste container allowing the contents to fall out Note To m...

Page 19: ...present an optical hazard although staring at the beam may cause temporary flash blindness WARNING Do not stare directly at the laser beam The laser must be used and maintained as detailed in this manual Never intentionally aim the laser beam at any person and prevent it from being directed towards the eye or an object other than the workpiece Always ensure that the laser beam is directed at the w...

Page 20: ... a complete halt Do not apply lateral pressure to the blade in an attempt to slow it down more quickly WARNING If the motor should stop or stall whilst a cut is being attempted release the trigger switch immediately and disconnect the machine from the power supply Remove the machine from the workpiece before investigating the cause and attempting to restart the motor Note This saw is fitted with a...

Page 21: ... brushes Fit the new brushes Refit the brush retaining caps Run the machine without load for several minutes after brush replacement This will aid the bedding in process Note If upon checking the brushes are found to be still serviceable they can be returned to their original position It is important that they are replaced in the same position as they were removed from the machine ENVIRONMENTAL PR...

Page 22: ... the Use of certain Hazardous Substances in Electrical Equipment RoHS Directive 2002 96 EC as The Waste Electrical and Electronic Equipment WEEE Directive amended by 2003 108 EC And is in conformity with the applicable requirements of the following documents EN55014 1 2006 EN55014 2 AA1 2001 EN61000 3 2 2006 EN61000 3 11 20000 EN60745 1 2009 EN60745 2 5 2007 Product Details Description EVOSAW230 2...

Page 23: ...23 www evolutionpowertools com EN ES FR NOTES ...

Page 24: ... Research Drive Davenport Iowa 52806 866 EVO TOOL EU Evolution Power Tools Ltd 61 Avenue Lafontaine 33560 Carbon Blanc Bordeaux 33 0 5 57 30 61 89 JP エボリューション パワーツール株式会社 544 0031 大阪府大阪市生野区 鶴橋5丁目21 19 0120 051 415 Discover Evolution Power Tools Visit www evolutionpowertools com or download the QR Reader App on your smart phone and scan the QR code Right ...

Reviews: