background image

3

5.0 

CLEANING

5.1 

To clean the filter cartridge element, carry out the following procedure:

1.  Unscrew the filter lid locking ring and remove the lid off the filter tank. In some cases 
where pressure has built up you will need to release air from the tank using the air bleed 
screw before removing the lid.

2.  Remove the cartridge element from the filter tank.

3.  Using a garden type hose clean the surface of the pleated elements. Make sure to 
clean between the pleats.

4. Place the cartridge element back into the filter tank ensuring that it is seated 
correctly.

5.  Ensure the lid o-ring is correctly seated on the lid groove, and lubricate with a 
suitable silicone lubricant if required.

6.  Push the lid onto the tank and screw the locking ring down.

7.  Refer to the start up procedure to recommence operation. 

5.2 

It is suggested that you should periodically remove the cartridge element and soak it 
overnight in a suitable cartridge cleaning compound. Soaking can aid with the extraction 
of debris not removed by hosing down the element.

5.3 

Cleaning intervals depend upon the swimming pool’s condition and use. Intervals 
between cleaning the element should not exceed a period of 12 months in any instance.

Fig. 1

Flow diagram.

Summary of Contents for Evoclear Trim Series

Page 1: ...qualified technician Improper installation can create electrical hazards which could result in property damage serious injury or death Improper installation will void the warranty This manual contain...

Page 2: ...TABLE OF CONTENTS 1 0 FOREWORD 1 2 0 INSTALLATION 1 3 0 START UP PROCEDURE 2 4 0 MAINTENANCE 2 5 0 CLEANING 3 6 0 TROUBLESHOOTING 4 7 0 NOTES 5...

Page 3: ...it into the required position Ensure it is on a flat level surface and aligned with the pump 2 4 It is advisable to bolt the filter to the floor in the required position to prevent movement Proper mou...

Page 4: ...me cases this may be required to be done a few times before the unit will remain primed and be fully operational 3 3 iCAUTION Do not stand over the lid whilst adjusting the air bleed to purge the syst...

Page 5: ...filter tank ensuring that it is seated correctly 5 Ensure the lid o ring is correctly seated on the lid groove and lubricate with a suitable silicone lubricant if required 6 Push the lid onto the tan...

Page 6: ...d or replaced Pool water level too low Pump not primed Pump impeller vanes blocked Strainer baskets not being used and or not being cleaned regularly Pump operating under speed low voltage Short filte...

Page 7: ...5 7 0 NOTES...

Page 8: ...icated copyright in the content of this document is the property of Evolution Water and Lighting Solutions under Australian copyright law Unless otherwise indicated content may not be reproduced or tr...

Reviews: