Evolution Aqua nexus 310 Installation And Instruction Manual Download Page 7

Evolution Aqua Ltd

Evolution House Kellet Close Wigan WN5 0LP E44(0)1942 216554

6

INSTALLATION EQUIPMENT REQUIRED

1. 

Pond Pump, with an actual flow rate that delivers to the filter a maximum of  

 

 

13.000 Ltrs/hour or the entire volume of water in the pond, every two hours,  

 

 

whichever is the greater.  

2. 

Air Pump. See table 1 on page 5.

3. 

A valve should be fitted before and after the Nexus so that the Nexus can be              

 

isolated if required. 

4. 

It is highly recommended that a suitably sized UV unit is installed with the Nexus for  

 

removal of single celled algae. UV systems are always installed after the pump.

NEXUS 310 PUMP FED INSTALLATION

Your Nexus 310 has been supplied to you ready for you to set up for Pump fed operation.

Pump Fed Installation Steps:

1. 

Attach the Hosetail assembly (fig 1) to the Nexus Inlet (A)

2. 

Connect the hose/pipework from your pump to the hosetail, cutting down the Hose 

 

tail to fit the correct hose, we recommend using 1

1

/

2

”.

3. 

Connect your 4” pipework from the Exit pipe (F) back to the Pond.

4. 

Pour the 2 x 50L K1 media bags into the outside chamber of the Nexus 

5. 

Connect your air pump to the Nexus air inlet (H) 

6. 

Connect the waste valves (G) to your waste outlet as described.

NEXUS 310 PUMP FED INSTALLATION

Fig 1

How to remove the clear lid 

from the Eazy. This is a tight 

fit. Do not remove the screws

H

A

G

F

Summary of Contents for nexus 310

Page 1: ...Evolution Aqua Ltd Evolution House Kellet Close Wigan WN5 0LP England 44 0 1942 216554 Filtration System Installation and instruction manual N31011311131MAN...

Page 2: ...ns back into your pond via gravity i e down a waterfall or through a large diameter pipe this is referred to as PUMP FED i e the water is fed to the filter using a pump ARE YOU GRA VITY FED By this we...

Page 3: ...ed media 14 How to get the best from your Nexus filter 15 Your Nexus comes complete with the following items TABLE OF CONTENTS Hose tail inlet assembly for use in pump fed setup only Bypass collar use...

Page 4: ...K1 media 40L for Nexus 310 which is located within the centre chamber of the Nexus After water en ters the Nexus it rotates around the Eazy in the centre chamber with a downward motion al lowing the...

Page 5: ...Evolution Aqua Ltd Evolution House Kellet Close Wigan WN5 0LP England 44 0 1942 216554 4 Filtration System Pump fed installation and operation manual...

Page 6: ...ot sufficient to support the Nexus using just blocks underneath the feet as this could lead to damage to the Nexus Incorrect installation will render the warranty invalid Check all the jubilee clips o...

Page 7: ...ems are always installed after the pump NEXUS 310 PUMP FED INSTALLATION Your Nexus 310 has been supplied to you ready for you to set up for Pump fed operation Pump Fed Installation Steps 1 Attach the...

Page 8: ...e line where it can pump directly to waste Once your Nexus is installed and plumbed in as described above you are ready to fill the Nexus and begin treating your pond water OPERATING YOUR NEXUS 310 PU...

Page 9: ...his would not be best practice Cleaning procedure 1 Close the valve at the Nexus inlet and immediately switch off your pump 2 Close the inlet to the inner chamber by inserting inlet slide plate suppli...

Page 10: ...The difference is clear at www evolutionaqua com 9 Filtration System Gravity fed installation and operation manual...

Page 11: ...low where you want the finished pond water surface to be Please see diagrams below The water on a Gravity fed system should be fed from an appropriately placed bottom drain through at least a 4 inch 1...

Page 12: ...3 1 2 Attach the 4 2 eazyconnector Fig 3 3 to the Nexus Outlet F Fig 3 2 3 Attach the 4 4 eazyconnector to the Nexus Inlet A Fig 3 4 and then to the 4 pipe work from your pond 4 Connect your water pum...

Page 13: ...an be connected using a waste pipe kit optional extra as shown in Figs 6 1 3 or can just be discharged individually If the Nexus is located below your drain height the waste can be either discharged i...

Page 14: ...rmally we would not recommend leaving the filter uncleaned more then 3 weeks The filter can be left longer if absolutely necessary but this would not be best practice Cleaning procedure 1 Switch off y...

Page 15: ...om the water As the K1 media chaotically circulates within the bio tank it causes old dead bacteria bio film on the outside to be removed making space for new younger heavier feeding bacteria bio film...

Page 16: ...bed The Pure Pond balls are made from a biodegradable polymer and crammed full of bacteria that are slowly released when they are needed most When you introduce the Pure Pond balls into the biologica...

Page 17: ...2 Though the warranty period may not have expired payment for repairs must be made in the following cases a When the fault is due to misuse or unauthorised repairs have been attempted b When the fault...

Page 18: ...orm will amount to your consent for us to disclose your details and other personal information to other companies within the Evolution Aqua group including any subsidiary company or subcontractor of E...

Reviews: