MANUFACTURED
IN THE UK
EAZYPOD AUTOMATIC
*NOTE: If the circulation pump does not switch on, then the waste valve is not fully closed and you
will see both the green and amber lights illuminated. This safety feature is built in to ensure that
you cannot empty your pond.
Cleaning is fully automated on the EazyPod Automatic, and is controlled
by a built-in timer, which is factory set at one clean every 3 days,
however, this is easily adjustable to fit in with your pond requirements.
The EazyPod Automatic will run a cleaning cycle which lasts
approximately 6 and a half minutes.
■
Adjustable timer kicks in to start a cleaning cycle.
■
The amber light on the control box illuminates.
■
Control box automatically switches circulating pump off.
■
Air pump inside the control box is switched on to clean the K1 Micro media.
■
After the K1 Micro media has been cleaned, the automated waste valve opens.
■
The EazyPod Automatic is drained to waste.
■
The automated waste valve closes. (Both green and amber lights are illuminated)
■
When the waste valve is fully closed, the air pump is switched off.
■
When only the green light is illuminated, the circulating pump switches back on.
■
EazyPod Automatic returns to filtration mode.
0
2
4
6.5
EazyPod Automatic cleaning cycle:
APPROX. CLEANING TIMES
(Mins)
EazyPod Automatic Cleaning Cycle
Adjusting the Cleaning Cycle
If you do not want to have your EazyPod cleaned once every 3 days, as is factory set, you can alter the
cleaning frequency to suit your needs. Simply turn SCREW A and SCREW B to point to the different
digits using the sequences shown in the tables below:
SCREW A - This screw sets the time of the cycle.
(Factory set pointing to 10 d)
Use a pozi-drive screwdriver to turn the screw head,
so the arrow on the dial points to the appropriate digit.
SCREW B - This screw sets the frequency as a
percentage of the time set above. (Factory set
pointing to 30%)